DC loadο
DC load describes how electrical demand responds to terminal voltage, frequency, or internal states. Static impedance/current/power components and dynamic load states produce different fault and recovery behavior, so the selected formulation materially changes system damping and voltage stability.
Typical useο
Use the formulation that matches the time scale and measured behavior of the represented demand.
Initialize active and reactive demand from the power flow and verify the voltage-dependence convention.
This model represents a DC load for EMT studies.
Purposeο
It is a DC EMT load model composed of a constant-power term and a conductance term.
Behaviorο
Uses DC bus voltage as its only external input.
Computes DC current and DC power.
Follows the EMT convention where current and power are positive when entering the bus.
A consuming DC load therefore produces negative DC current and negative DC power in this sign convention.
Characteristicsο
Algebraic DC EMT load model.
Suitable for DC-side network studies.
Very simple and computationally light.
Characteristic equationsο
Interface tableο
Category |
Name |
Meaning |
Units |
|---|---|---|---|
Input |
|
DC bus voltage at the load connection point |
pu |
Output |
|
DC current entering the bus from the load model sign convention |
pu |
Variable |
|
Algebraic DC current variable |
pu |
Variable |
|
Algebraic DC power variable |
pu |
Parameter |
|
Constant-power load term used by the DC load equation |
pu |
Parameter |
|
Conductance term of the DC load |
pu |
How to use itο
Use this template when you need a simple DC load in EMT studies.
If the DC load must have switching, converter control, or dynamic energy-storage behavior, use a more detailed model instead.