Double cage induction motor

Double cage induction motor belongs to an electromechanical machine or prime-mover model. It links electrical torque and flux with rotor speed, angle, mechanical power, or actuator dynamics, making it central to frequency, voltage, and rotor-angle stability studies.

Typical use

  • Use it when electrical transients must interact with rotating mass or machine controls.

  • Initialize torque, power, flux, and speed consistently with the solved power flow.

This model represents a double-cage induction motor in phase-domain EMT form.

Scope and model level

This is the Level-3 induction-motor model. Like the single-cage model, it uses a three-wire ABC stator interface and stationary \alpha\beta electrical coordinates. It adds a second rotor cage so the equivalent rotor impedance changes naturally with slip. This improves the representation of starting torque, inrush current, and deep-bar behavior.

Use Level 3 when both running and high-slip characteristics must be matched. Use the simpler Level-2 model when one cage fits the study data and the extra parameters cannot be identified reliably.

State equations

The model retains stator flux, two pairs of rotor-cage fluxes, and normalized rotor speed. The stator flux follows

\dot\psi_{s,\alpha}=v_\alpha-r_si_{s,\alpha},
\qquad
\dot\psi_{s,\beta}=v_\beta-r_si_{s,\beta}.

For cage k\in\{1,2\},

\dot\psi_{rk,\alpha}=-r_{rk}i_{rk,\alpha}-\omega_{r,e}\psi_{rk,\beta},

\dot\psi_{rk,\beta}=-r_{rk}i_{rk,\beta}+\omega_{r,e}\psi_{rk,\alpha}.

The coupled inductance matrix determines stator and cage currents from all six flux components. Electromagnetic torque is computed from stator flux and current, and the shaft equation is

\dot\omega_r=\frac{T_e-T_m-d(\omega_r-1)}{2h+\varepsilon},
\qquad s=1-\omega_r.

Initialization

The initializer forms a positive-sequence double-cage equivalent circuit from solved terminal voltage and power. It estimates a bounded slip, divides rotor current between the two cage impedances, and seeds stator flux, both cage fluxes, speed, and torque consistently. The two cage parameter sets must be physically distinct and use the same per-unit base; otherwise the added model order provides no reliable benefit.

Numerical and physical limits

This is still a symmetrical three-phase machine model, although unbalanced ABC terminal waveforms are accepted during EMT simulation. The additional rotor time constant can make the system stiffer than the single-cage model. Inspect both cage currents during starting and faults, and use time-step convergence when one cage has very small leakage or resistance.

Interface table

Category

Name

Meaning

Units

Input

v_A

Instantaneous phase-A terminal voltage applied to the motor stator

pu

Input

v_B

Instantaneous phase-B terminal voltage applied to the motor stator

pu

Input

v_C

Instantaneous phase-C terminal voltage applied to the motor stator

pu

Output

i_A

Phase-A current injected by the motor model into the EMT network

pu

Output

i_B

Phase-B current injected by the motor model into the EMT network

pu

Output

i_C

Phase-C current injected by the motor model into the EMT network

pu

Variable

psi_s_alpha

Alpha-axis stator flux linkage state

pu

Variable

psi_s_beta

Beta-axis stator flux linkage state

pu

Variable

psi_r1_alpha

Alpha-axis flux linkage of the first rotor cage

pu

Variable

psi_r1_beta

Beta-axis flux linkage of the first rotor cage

pu

Variable

psi_r2_alpha

Alpha-axis flux linkage of the second rotor cage

pu

Variable

psi_r2_beta

Beta-axis flux linkage of the second rotor cage

pu

Variable

omega_r

Rotor electrical speed state

pu

Variable

i_s_alpha

Alpha-axis stator current derived from the flux states

pu

Variable

i_s_beta

Beta-axis stator current derived from the flux states

pu

Variable

i_r1_alpha

Alpha-axis current in the first rotor cage

pu

Variable

i_r1_beta

Beta-axis current in the first rotor cage

pu

Variable

i_r2_alpha

Alpha-axis current in the second rotor cage

pu

Variable

i_r2_beta

Beta-axis current in the second rotor cage

pu

Variable

P_motor

Instantaneous three-phase active power absorbed by the motor

pu

Variable

Q_motor

Instantaneous three-phase reactive power absorbed by the motor

pu

Variable

T_e

Electromagnetic torque produced by the motor

pu

Variable

T_m

Mechanical load torque opposing the electromagnetic torque

pu

Variable

slip

Rotor slip relative to synchronous speed

pu

Parameter

r_s

Stator resistance

pu

Parameter

r_r1

Rotor resistance of the first cage

pu

Parameter

x_lr1

Rotor leakage reactance of the first cage

pu

Parameter

r_r2

Rotor resistance of the second cage

pu

Parameter

x_lr2

Rotor leakage reactance of the second cage

pu

Parameter

x_ls

Stator leakage reactance

pu

Parameter

x_m

Magnetizing reactance shared by stator and rotor cages

pu

Parameter

h

Inertia constant of the motor shaft system

s

Parameter

d

Mechanical damping coefficient

pu torque/pu speed

Parameter

omega_base

Base electrical angular frequency used to scale the state equations

rad/s

Parameter

t_load_nom

Nominal mechanical load torque used by the internal load model

pu

Parameter

p0_a

Initial phase-A active-power operating point used for initialization

pu

Parameter

p0_b

Initial phase-B active-power operating point used for initialization

pu

Parameter

p0_c

Initial phase-C active-power operating point used for initialization

pu

Parameter

q0_a

Initial phase-A reactive-power operating point used for initialization

pu

Parameter

q0_b

Initial phase-B reactive-power operating point used for initialization

pu

Parameter

q0_c

Initial phase-C reactive-power operating point used for initialization

pu

How to use it

  1. Connect all three stator phases and map stator, magnetizing, mechanical, and both cage parameter sets.

  2. Initialize from a converged operating point and verify total power, slip, and torque balance.

  3. Compare starting current and torque against manufacturer or test data when tuning the two cages.

  4. Prefer the single-cage model if only normal-running behavior is known.

  5. Monitor speed, slip, both cage currents, and electromagnetic torque during severe voltage events.