Exciter

Exciter belongs to an electromechanical machine or prime-mover model. It links electrical torque and flux with rotor speed, angle, mechanical power, or actuator dynamics, making it central to frequency, voltage, and rotor-angle stability studies.

Typical use

  • Use it when electrical transients must interact with rotating mass or machine controls.

  • Initialize torque, power, flux, and speed consistently with the solved power flow.

This model represents the EMT excitation control block used with the complete generator model.

Purpose

It is the EMT excitation controller built by get_exciter_emt().

Behavior

  • Receives machine exciter-feedback quantity, three-phase terminal voltages, and stabilizer signal.

  • Builds a voltage-magnitude measurement from the three phase voltages.

  • Filters the measurement and forms a regulated voltage error.

  • Applies lead-lag AVR action, limit logic, and field-stage dynamics.

  • Produces the field-voltage signal sent to the machine block.

Characteristics

  • EMT excitation control block.

  • Includes voltage filtering, AVR dynamics, limiter logic, and nonlinear field feedback.

Block structure

abc voltage measurement
  -> voltage magnitude Vm
  -> voltage filter
  -> reference / PSS error
  -> lead-lag AVR
  -> limiter and field feedback
  -> field stage
  -> Vf

Characteristic equations

V_m = \sqrt{\frac{v_A^2 + v_B^2 + v_C^2}{3}}

e_{exc} = U_{s,ref} + V_{pss} - y_1 - y_2

y_{LL} = y_3 + \frac{t_C}{t_B}(e_{exc} - y_3)

\frac{dy_1}{dt} = \frac{V_m - y_1}{t_R}

\frac{dy_2}{dt} = \frac{K_f V_f - y_2}{t_F}

\frac{dy_3}{dt} = \frac{e_{exc} - y_3}{t_B}

\frac{dy_4}{dt} = \frac{K_a y_{LL} - y_4}{t_A}

\frac{dV_f}{dt} = \frac{V_{field,ref} - V_{field,fb}}{t_E}

Interface table

Category

Name

Meaning

Units

Input

IRPu

Exciter-feedback quantity received from the machine block

pu

Input

v_A

Phase-A terminal voltage used by the exciter voltage-magnitude measurement

pu

Input

v_B

Phase-B terminal voltage used by the exciter voltage-magnitude measurement

pu

Input

v_C

Phase-C terminal voltage used by the exciter voltage-magnitude measurement

pu

Input

V_pss

Stabilizer signal received from the stabilizer block

pu

Output

Vf

Field-voltage signal sent to the machine block

pu

Variable

Vm

Measured voltage magnitude used by the AVR

pu

Variable

Efe

Internal exciter-field variable after limiter action

pu

Variable

UsRefPu

Voltage reference used by the AVR loop

pu

Variable

y_exciter1

Voltage-measurement filter state

pu

Variable

y_exciter2

Rate-feedback state/output variable

pu

Variable

y_exciter3

Lead-lag internal state

pu

Variable

y_exciter4

AVR internal state

pu

Variable

VeMaxPu

Dynamic ceiling variable used by one limiter stage

pu

Variable

u_aux

Auxiliary nonlinear field-feedback variable

pu

Parameter

Ka

AVR gain

pu/pu

Parameter

Kf

Rate-feedback gain

pu/pu

Parameter

tA

AVR stage time constant

s

Parameter

tB

Lead-lag lag time constant

s

Parameter

tC

Lead-lag lead time constant

s

Parameter

tE

Field-stage time constant

s

Parameter

tF

Rate-feedback time constant

s

Parameter

tR

Voltage measurement filter time constant

s

Parameter

Kd

Demagnetizing/field-feedback factor

pu

Parameter

Ke

Field-feedback coefficient

pu

Parameter

Kfd

Field conversion factor

pu

Parameter

AEz

Saturation-law shaping coefficient

pu

Parameter

BEz

Saturation-law exponential coefficient

1/pu

Parameter

AEx

Exponential field-feedback coefficient

pu

Parameter

BEx

Exponential field-feedback exponent coefficient

1/pu

Parameter

Se_threshold

Threshold at which the nonlinear field saturation becomes active

pu

Parameter

VaMaxPu

Upper AVR output limit

pu

Parameter

VaMinPu

Lower AVR output limit

pu

Parameter

VfeMaxPu

Upper field-output related limit

pu

Parameter

EfeMaxPu

Upper internal exciter-field limit

pu

Parameter

EfeMinPu

Lower internal exciter-field limit

pu

How to use it

  • Treat this as the field-voltage control block of the EMT Complete generator package.

  • It is not a standalone source or sink for the network.