from __future__ import annotations
import numpy as np
from scipy.sparse import lil_matrix
from cmath import rect
from typing import Dict, Union, TYPE_CHECKING
from VeraGridEngine.basic_structures import Logger
import VeraGridEngine.Devices as dev
from VeraGridEngine.Devices.Substation.bus import Bus
from VeraGridEngine.Devices.Fluid.fluid_injection_template import FluidInjectionTemplate
from VeraGridEngine.Devices.Aggregation.area import Area
from VeraGridEngine.enumerations import (BusMode, BranchImpedanceMode, ExternalGridMode, DeviceType,
TapModuleControl, TapPhaseControl, HvdcControlType, ConverterControlType,
ShuntConnectionType, ShuntControlMode, GeneratorControlMode, WindingType,
StaticGeneratorControlMode)
from VeraGridEngine.basic_structures import BoolVec, IntVec
from VeraGridEngine.Devices.types import BRANCH_TYPES
from VeraGridEngine.DataStructures.battery_data import BatteryData
from VeraGridEngine.DataStructures.passive_branch_data import PassiveBranchData
from VeraGridEngine.DataStructures.active_branch_data import ActiveBranchData
from VeraGridEngine.DataStructures.bus_data import BusData
from VeraGridEngine.DataStructures.generator_data import GeneratorData
from VeraGridEngine.DataStructures.hvdc_data import HvdcData
from VeraGridEngine.DataStructures.vsc_data import VscData
from VeraGridEngine.DataStructures.load_data import LoadData
from VeraGridEngine.DataStructures.shunt_data import ShuntData
from VeraGridEngine.DataStructures.fluid_node_data import FluidNodeData
from VeraGridEngine.DataStructures.fluid_turbine_data import FluidTurbineData
from VeraGridEngine.DataStructures.fluid_pump_data import FluidPumpData
from VeraGridEngine.DataStructures.fluid_p2x_data import FluidP2XData
from VeraGridEngine.DataStructures.fluid_path_data import FluidPathData
from VeraGridEngine.DataStructures.numerical_circuit import NumericalCircuit
from VeraGridEngine.Utils.NumericalMethods.common import fortescue_012_to_abc
if TYPE_CHECKING: # Only imports the below statements during type checking
from VeraGridEngine.Devices.multi_circuit import MultiCircuit
from VeraGridEngine.Simulations.OPF.opf_results import OptimalPowerFlowResults
from VeraGridEngine.Simulations.OPF.opf_ts_results import OptimalPowerFlowTimeSeriesResults
from VeraGridEngine.Simulations.NTC.ntc_results import OptimalNetTransferCapacityResults
from VeraGridEngine.Simulations.NTC.ntc_ts_results import OptimalNetTransferCapacityTimeSeriesResults
from VeraGridEngine.Simulations import OptimalNetTransferCapacityResults
VALID_OPF_RESULTS = Union[
OptimalPowerFlowResults,
OptimalPowerFlowTimeSeriesResults,
OptimalNetTransferCapacityResults,
OptimalNetTransferCapacityTimeSeriesResults
]
[docs]
def delta2StarAdmittance(Yab: complex,
Ybc: complex,
Yca: complex):
"""
Converts Delta to Star in admittances
:param Yab:
:param Ybc:
:param Yca:
:return: Ya, Yb, Yc
"""
return 1 / 3 * np.array([
[0, 0, 0, 0],
[0, Yab + Yca, -Yab, -Yca],
[0, -Yab, Yab + Ybc, -Ybc],
[0, -Yca, -Ybc, Ybc + Yca]
])
[docs]
def set_bus_control_voltage(i: int,
j: int,
remote_control: bool,
bus_name: str,
bus_voltage_used: BoolVec,
bus_data: BusData,
candidate_Vm: float,
use_stored_guess: bool,
logger: Logger) -> None:
"""
Set the bus control voltage
:param i: Bus index
:param j: Remote Bus index
:param remote_control: Using remote control?
:param bus_name: Bus name
:param bus_voltage_used: Array of flags indicating if a bus voltage has been modified before
:param bus_data: BusData
:param candidate_Vm: Voltage set point that you want to set
:param use_stored_guess: Use the stored seed values?
:param logger: Logger
"""
if bus_data.bus_types[i] != BusMode.Slack_tpe.value: # if it is not Slack
if remote_control and j > -1 and j != i:
# delete voltage control
# bus_data.bus_types[j] = BusMode.PQV_tpe.value # remote bus to PQV type
bus_data.set_bus_mode(j, BusMode.PQV_tpe)
# bus_data.bus_types[i] = BusMode.P_tpe.value # local bus to P type
bus_data.set_bus_mode(i, BusMode.P_tpe)
else:
# local voltage control
# bus_data.bus_types[i] = BusMode.PV_tpe.value # set as PV
bus_data.set_bus_mode(i, BusMode.PV_tpe)
controlled_bus_idx = j if remote_control and j > -1 and j != i else i
if not bus_voltage_used[controlled_bus_idx]:
existing_angle = np.angle(bus_data.Vbus[controlled_bus_idx])
bus_data.Vbus[controlled_bus_idx] = rect(candidate_Vm, existing_angle)
bus_voltage_used[controlled_bus_idx] = True
elif not np.isclose(candidate_Vm, abs(bus_data.Vbus[controlled_bus_idx])):
logger.add_error(msg='Different control voltage set points',
device=bus_name,
value=candidate_Vm,
expected_value=abs(bus_data.Vbus[controlled_bus_idx]))
[docs]
def normalize_upper_bound(lower: float,
upper: float,
logger: Logger,
device_name: str,
device_class: str,
lower_name: str,
upper_name: str) -> tuple[float, float]:
"""
Normalize a scalar box constraint so the upper bound is never below the lower bound.
:param lower: Lower bound candidate.
:param upper: Upper bound candidate.
:param logger: Logger used to report the correction.
:param device_name: Device name for the log entry.
:param device_class: Device class for the log entry.
:param lower_name: Human-readable lower-bound field name.
:param upper_name: Human-readable upper-bound field name.
:return: Tuple ``(lower, upper)`` with ``upper >= lower`` enforced.
"""
lower_value: float = float(lower)
upper_value: float = float(upper)
# The LP/MIP formulations assume valid boxes. If the source data reverses the interval, clamp
# the upper bound to the lower bound so the box degenerates to one feasible point instead of
# becoming invalid and crashing the optimization model.
if upper_value < lower_value:
logger.add_warning(
msg=f"Invalid bounds corrected: {upper_name} < {lower_name}",
device=device_name,
value=upper_value,
expected_value=lower_value,
device_class=device_class,
comment=f"Setting {upper_name} = {lower_name}",
device_property=upper_name,
)
upper_value = lower_value
else:
pass
return lower_value, upper_value
[docs]
def set_bus_control_voltage_vsc(i: int,
j: int,
remote_control: bool,
bus_name: str,
bus_voltage_used: BoolVec,
bus_data: BusData,
candidate_Vm: float,
use_stored_guess: bool,
logger: Logger) -> None:
"""
Set the bus control voltage
:param i: Bus index
:param j: Remote Bus index
:param remote_control: Using remote control?
:param bus_name: Bus name
:param bus_voltage_used: Array of flags indicating if a bus voltage has been modified before
:param bus_data: BusData
:param candidate_Vm: Voltage set point that you want to set
:param use_stored_guess: Use the stored seed values?
:param logger: Logger
"""
if bus_data.bus_types[i] != BusMode.Slack_tpe.value: # if it is not Slack
if remote_control and j > -1 and j != i:
# delete voltage control
# bus_data.bus_types[j] = BusMode.PQV_tpe.value # remote bus to PQV type
# bus_data.set_bus_mode(j, BusMode.PQV_tpe)
bus_data.is_p_controlled[j] = True
bus_data.is_q_controlled[j] = True
bus_data.is_vm_controlled[j] = True
# bus_data.bus_types[i] = BusMode.P_tpe.value # local bus to P type
# bus_data.set_bus_mode(i, BusMode.P_tpe)
bus_data.is_p_controlled[i] = True
else:
# local voltage control
# bus_data.bus_types[i] = BusMode.PV_tpe.value # set as PV
# bus_data.set_bus_mode(i, BusMode.PV_tpe)
bus_data.is_p_controlled[i] = True
bus_data.is_vm_controlled[i] = True
if not use_stored_guess:
if not bus_voltage_used[i]:
if remote_control and j > -1 and j != i:
# initialize the remote bus voltage to the control value but preserve angle while updating magnitude
existing_angle = np.angle(bus_data.Vbus[j])
bus_data.Vbus[j] = complex(candidate_Vm, 0) * np.exp(1j * existing_angle)
bus_voltage_used[j] = True
else:
# initialize the local bus voltage to the control value but preserve angle while updating magnitude
existing_angle = np.angle(bus_data.Vbus[i])
bus_data.Vbus[i] = complex(candidate_Vm, 0) * np.exp(1j * existing_angle)
bus_voltage_used[i] = True
elif candidate_Vm != bus_data.Vbus[i]:
logger.add_error(msg='Different control voltage set points',
device=bus_name,
value=candidate_Vm,
expected_value=bus_data.Vbus[i])
[docs]
def set_bus_control_angle_vsc(i: int,
j: int,
remote_control: bool,
bus_name: str,
bus_angle_used: BoolVec,
bus_data: BusData,
candidate_Va: float,
use_stored_guess: bool,
logger: Logger) -> None:
"""
Set the bus control angle
:param i: Bus index
:param j: Remote Bus index
:param remote_control: Using remote control?
:param bus_name: Bus name
:param bus_angle_used: Array of flags indicating if a bus angle has been modified before
:param bus_data: BusData
:param candidate_Va: Angle set point that you want to set in degrees
:param use_stored_guess: Use the stored seed values?
:param logger: Logger
"""
if bus_data.bus_types[i] != BusMode.Slack_tpe.value: # if it is not Slack
if remote_control and j > -1 and j != i:
# delete angle control
# bus_data.bus_types[j] = BusMode.PQV_tpe.value # remote bus to PQV type
# bus_data.set_bus_mode(j, BusMode.PQV_tpe)
bus_data.is_p_controlled[j] = True
bus_data.is_q_controlled[j] = True
bus_data.is_va_controlled[j] = True
# bus_data.bus_types[i] = BusMode.P_tpe.value # local bus to P type
# bus_data.set_bus_mode(i, BusMode.P_tpe)
bus_data.is_p_controlled[i] = True
else:
# local angle control controlling q as well
# bus_data.bus_types[i] = BusMode.PV_tpe.value # set as PV
# bus_data.set_bus_mode(i, BusMode.PV_tpe)
bus_data.is_q_controlled[i] = True
bus_data.is_va_controlled[i] = True
if not use_stored_guess:
if not bus_angle_used[i]:
if remote_control and j > -1 and j != i:
# initialize the remote bus angle to the control value but preserve magnitude while updating angle
existing_magnitude = np.abs(bus_data.Vbus[j])
bus_data.Vbus[j] = existing_magnitude * np.exp(1j * candidate_Va * np.pi / 180)
bus_angle_used[j] = True
else:
# initialize the local bus angle to the control value but preserve magnitude while updating angle
existing_magnitude = np.abs(bus_data.Vbus[i])
bus_data.Vbus[i] = existing_magnitude * np.exp(1j * candidate_Va * np.pi / 180)
bus_angle_used[i] = True
else:
existing_angle = np.angle(bus_data.Vbus[i])
if not np.isclose(candidate_Va, existing_angle):
logger.add_error(msg='Different control angle set points',
device=bus_name,
value=candidate_Va,
expected_value=existing_angle)
[docs]
def set_bus_control_voltage_hvdc(i: int,
j: int,
remote_control: bool,
bus_name: str,
bus_voltage_used: BoolVec,
bus_data: BusData,
candidate_Vm: float,
use_stored_guess: bool,
logger: Logger) -> None:
"""
Set the bus control voltage
:param i: Bus index
:param j: Remote Bus index
:param remote_control: Using remote control?
:param bus_name: Bus name
:param bus_voltage_used: Array of flags indicating if a bus voltage has been modified before
:param bus_data: BusData
:param candidate_Vm: Voltage set point that you want to set
:param use_stored_guess: Use the stored seed values?
:param logger: Logger
"""
if bus_data.bus_types[i] != BusMode.Slack_tpe.value: # if it is not Slack
# local voltage control
bus_data.bus_types[i] = BusMode.PV_tpe.value # set as PV
# bus_data.set_bus_mode(i, BusMode.PV_tpe)
bus_data.is_p_controlled[i] = True
bus_data.is_vm_controlled[i] = True
bus_data.is_q_controlled[i] = True
if not use_stored_guess:
if not bus_voltage_used[i]:
if remote_control and j > -1 and j != i:
# initialize the remote bus voltage to the control value
bus_data.Vbus[j] = complex(candidate_Vm, 0)
bus_voltage_used[j] = True
else:
# initialize the local bus voltage to the control value
bus_data.Vbus[i] = complex(candidate_Vm, 0)
bus_voltage_used[i] = True
elif candidate_Vm != bus_data.Vbus[i]:
logger.add_error(msg='Different control voltage set points',
device=bus_name,
value=candidate_Vm,
expected_value=bus_data.Vbus[i])
[docs]
def get_bus_data(bus_data: BusData,
circuit: MultiCircuit,
areas_dict: Dict[Area, int],
t_idx: int | None,
use_stored_guess=False,
consider_grounded_buses: bool = False,
logger: Logger = Logger()) -> None:
"""
:param bus_data: BusData
:param circuit:
:param areas_dict:
:param t_idx:
:param use_stored_guess:
:param consider_grounded_buses:
:param logger:
:return:
"""
substation_dict = {sub: i for i, sub in enumerate(circuit.substations)}
for i, bus in enumerate(circuit.buses):
# bus parameters
bus_data.original_idx[i] = i
bus_data.names[i] = bus.name
bus_data.idtag[i] = bus.idtag
bus_data.Vnom[i] = bus.Vnom
bus_data.cost_v[i] = bus.Vm_cost
bus_data.Vbus[i] = bus.get_voltage_guess_at(t_idx=t_idx, use_stored_guess=use_stored_guess)
bus_data.is_dc[i] = bus.is_dc
# Grounded buses go to zero
if bus.is_grounded and consider_grounded_buses and bus.is_dc:
bus_data.Vbus[i] = 1e-20 * np.exp(1j * 1e-20) # effectively zero
bus_data.is_grounded[i] = bus.is_grounded
else:
bus_data.is_grounded[i] = False
angle_min, angle_max = normalize_upper_bound(
lower=bus.angle_min,
upper=bus.angle_max,
logger=logger,
device_name=bus.name,
device_class=str(bus.device_type.value),
lower_name="angle_min",
upper_name="angle_max",
)
bus_data.angle_min[i] = angle_min
bus_data.angle_max[i] = angle_max
if bus.get_is_slack_at(t=t_idx):
# bus_data.bus_types[i] = BusMode.Slack_tpe.value # VD
bus_data.set_bus_mode(i, BusMode.Slack_tpe)
else:
# PQ by default, later it is modified by generators and batteries
# bus_data.bus_types[i] = BusMode.PQ_tpe.value
bus_data.set_bus_mode(i, BusMode.PQ_tpe)
bus_data.substations[i] = substation_dict.get(bus.substation, 0)
bus_data.areas[i] = areas_dict.get(bus.area, 0)
bus_data.active[i] = bus.get_active_at(t_idx)
bus_data.Vmin[i] = bus.get_Vmin_at(t_idx)
bus_data.Vmax[i] = bus.get_Vmax_at(t_idx)
return None
[docs]
def get_load_data(data: LoadData,
circuit: MultiCircuit,
bus_dict: Dict[Bus, int],
bus_voltage_used: BoolVec,
bus_data: BusData,
t_idx: int | None,
logger: Logger,
use_stored_guess: bool = False,
opf_results: Union[OptimalPowerFlowResults, None] = None,
fill_three_phase: bool = False) -> LoadData:
"""
:param data:
:param circuit:
:param bus_dict:
:param bus_voltage_used:
:param bus_data:
:param logger:
:param t_idx:
:param opf_results:
:param use_stored_guess:
:param fill_three_phase: Fill the tree phase info?
:return:
"""
ii = 0
for elm in circuit.get_loads():
if elm.bus is None:
data.bus_idx[ii] = -1
data.active[ii] = False
else:
i = bus_dict[elm.bus]
data.names[ii] = elm.name
data.idtag[ii] = elm.idtag
data.bus_idx[ii] = i
data.original_idx[ii] = ii
data.mttf[ii] = elm.mttf
data.mttr[ii] = elm.mttr
data.scalable[ii] = elm.scalable
if opf_results is not None:
if opf_results.load_shedding.ndim == 1:
data.S[ii] = elm.get_S_at(t_idx) - opf_results.load_shedding[ii]
elif opf_results.load_shedding.ndim == 2:
data.S[ii] = elm.get_S_at(t_idx) - opf_results.load_shedding[t_idx, ii]
else:
data.S[ii] = elm.get_S_at(t_idx) # ???
else:
data.S[ii] = elm.get_S_at(t_idx)
if fill_three_phase:
if elm.conn == ShuntConnectionType.GroundedStar:
S_abc = any([elm.get_Sa_at(t_idx), elm.get_Sb_at(t_idx), elm.get_Sc_at(t_idx)])
if not S_abc:
data.S3_star[4 * ii + 1] = elm.get_S_at(t_idx) / 3
data.S3_star[4 * ii + 2] = elm.get_S_at(t_idx) / 3
data.S3_star[4 * ii + 3] = elm.get_S_at(t_idx) / 3
else:
data.S3_star[4 * ii + 1] = elm.get_Sa_at(t_idx)
data.S3_star[4 * ii + 2] = elm.get_Sb_at(t_idx)
data.S3_star[4 * ii + 3] = elm.get_Sc_at(t_idx)
I_abc = any(
[np.conj(elm.get_I1_at(t_idx)), np.conj(elm.get_I2_at(t_idx)), np.conj(elm.get_I3_at(t_idx))])
if not I_abc:
data.I3_star[4 * ii + 1] = np.conj(elm.get_I_at(t_idx)) / 3
data.I3_star[4 * ii + 2] = np.conj(elm.get_I_at(t_idx)) / 3
data.I3_star[4 * ii + 3] = np.conj(elm.get_I_at(t_idx)) / 3
else:
data.I3_star[4 * ii + 1] = np.conj(elm.get_I1_at(t_idx))
data.I3_star[4 * ii + 2] = np.conj(elm.get_I2_at(t_idx))
data.I3_star[4 * ii + 3] = np.conj(elm.get_I3_at(t_idx))
Y_abc = any([elm.get_Y1_at(t_idx), elm.get_Y2_at(t_idx), elm.get_Y3_at(t_idx)])
if not Y_abc:
if elm.conn == ShuntConnectionType.NeutralStar:
data.Y3_star[4 * ii + 0, 1] = -1 * elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 0, 2] = -1 * elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 0, 3] = -1 * elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 1, 1] = elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 2, 2] = elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 3, 3] = elm.get_Y_at(t_idx) / 3
else:
data.Y3_star[4 * ii + 1, 1] = elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 2, 2] = elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 3, 3] = elm.get_Y_at(t_idx) / 3
else:
if elm.conn == ShuntConnectionType.NeutralStar:
data.Y3_star[4 * ii + 0, 1] = -1 * elm.get_Y1_at(t_idx)
data.Y3_star[4 * ii + 0, 2] = -1 * elm.get_Y2_at(t_idx)
data.Y3_star[4 * ii + 0, 3] = -1 * elm.get_Y3_at(t_idx)
data.Y3_star[4 * ii + 1, 1] = elm.get_Y1_at(t_idx)
data.Y3_star[4 * ii + 2, 2] = elm.get_Y2_at(t_idx)
data.Y3_star[4 * ii + 3, 3] = elm.get_Y3_at(t_idx)
else:
data.Y3_star[4 * ii + 1, 1] = elm.get_Y1_at(t_idx)
data.Y3_star[4 * ii + 2, 2] = elm.get_Y2_at(t_idx)
data.Y3_star[4 * ii + 3, 3] = elm.get_Y3_at(t_idx)
elif elm.conn == ShuntConnectionType.FloatingStar:
# Admittances
Ya = elm.get_Y1_at(t_idx)
Yb = elm.get_Y2_at(t_idx)
Yc = elm.get_Y3_at(t_idx)
if Ya != 0.0 + 0.0j and Yb != 0.0 + 0.0j and Yc != 0.0 + 0.0j:
data.A_floatingstar[ii] = Ya / (Ya + Yb + Yc)
data.B_floatingstar[ii] = Yb / (Ya + Yb + Yc)
data.C_floatingstar[ii] = Yc / (Ya + Yb + Yc)
A = Ya / (Ya + Yb + Yc)
B = Yb / (Ya + Yb + Yc)
C = Yc / (Ya + Yb + Yc)
# First row
data.Y3_star[4 * ii + 1, 1] = (1 - A) * Ya
data.Y3_star[4 * ii + 1, 2] = -B * Ya
data.Y3_star[4 * ii + 1, 3] = -C * Ya
# Second row
data.Y3_star[4 * ii + 2, 1] = -A * Yb
data.Y3_star[4 * ii + 2, 2] = (1 - B) * Yb
data.Y3_star[4 * ii + 2, 3] = -C * Yb
# Third row
data.Y3_star[4 * ii + 3, 1] = -A * Yc
data.Y3_star[4 * ii + 3, 2] = -B * Yc
data.Y3_star[4 * ii + 3, 3] = (1 - C) * Yc
# Currents
Ia = np.conj(elm.get_I1_at(t_idx))
Ib = np.conj(elm.get_I2_at(t_idx))
Ic = np.conj(elm.get_I3_at(t_idx))
if Ia != 0.0 + 0.0j and Ib != 0.0 + 0.0j and Ic != 0.0 + 0.0j:
data.I3_floatingstar[4 * ii + 1] = Ia
data.I3_floatingstar[4 * ii + 2] = Ib
data.I3_floatingstar[4 * ii + 3] = Ic
# Powers
Sa = elm.get_Sa_at(t_idx)
Sb = elm.get_Sb_at(t_idx)
Sc = elm.get_Sc_at(t_idx)
if Sa != 0.0 + 0.0j and Sb != 0.0 + 0.0j and Sc != 0.0 + 0.0j:
data.S3_floatingstar[4 * ii + 1] = Sa
data.S3_floatingstar[4 * ii + 2] = Sb
data.S3_floatingstar[4 * ii + 3] = Sc
elif elm.conn == ShuntConnectionType.NeutralStar:
# Admittance
Ya = elm.get_Y1_at(t_idx)
Yb = elm.get_Y2_at(t_idx)
Yc = elm.get_Y3_at(t_idx)
# First row
data.Y3_star[4 * ii + 0, 0] = Ya + Yb + Yc + 1e-4
data.Y3_star[4 * ii + 0, 1] = -Ya
data.Y3_star[4 * ii + 0, 2] = -Yb
data.Y3_star[4 * ii + 0, 3] = -Yc
# Second row
data.Y3_star[4 * ii + 1, 0] = -Ya
data.Y3_star[4 * ii + 1, 1] = Ya
# Third row
data.Y3_star[4 * ii + 2, 0] = -Yb
data.Y3_star[4 * ii + 2, 2] = Yb
# Fourth row
data.Y3_star[4 * ii + 3, 0] = -Yc
data.Y3_star[4 * ii + 3, 3] = Yc
# Current
data.I3_star[4 * ii + 0] = -np.conj(elm.get_I1_at(t_idx)) - np.conj(elm.get_I2_at(t_idx)) - np.conj(
elm.get_I3_at(t_idx))
data.I3_star[4 * ii + 1] = np.conj(elm.get_I1_at(t_idx))
data.I3_star[4 * ii + 2] = np.conj(elm.get_I2_at(t_idx))
data.I3_star[4 * ii + 3] = np.conj(elm.get_I3_at(t_idx))
# Current
data.S3_star[4 * ii + 0] = -elm.get_Sa_at(t_idx) - elm.get_Sb_at(t_idx) - elm.get_Sc_at(t_idx)
data.S3_star[4 * ii + 1] = elm.get_Sa_at(t_idx)
data.S3_star[4 * ii + 2] = elm.get_Sb_at(t_idx)
data.S3_star[4 * ii + 3] = elm.get_Sc_at(t_idx)
elif elm.conn == ShuntConnectionType.Delta:
data.S3_delta[4 * ii + 1] = elm.get_Sa_at(t_idx)
data.S3_delta[4 * ii + 2] = elm.get_Sb_at(t_idx)
data.S3_delta[4 * ii + 3] = elm.get_Sc_at(t_idx)
data.I3_delta[4 * ii + 1] = np.conj(elm.get_I1_at(t_idx))
data.I3_delta[4 * ii + 2] = np.conj(elm.get_I2_at(t_idx))
data.I3_delta[4 * ii + 3] = np.conj(elm.get_I3_at(t_idx))
data.Y3_star[4 * ii:4 * ii + 4, [0, 1, 2, 3]] = delta2StarAdmittance(
Yab=elm.get_Y1_at(t_idx),
Ybc=elm.get_Y2_at(t_idx),
Yca=elm.get_Y3_at(t_idx)
)
else:
raise Exception(f"Unhandled connection type {elm.conn}")
data.I[ii] = elm.get_I_at(t_idx)
data.Y[ii] = elm.get_Y_at(t_idx)
data.active[ii] = elm.get_active_at(t_idx)
data.cost[ii] = elm.get_Cost_at(t_idx)
data.shift_key[ii] = elm.get_shift_key_at(t_idx)
if elm.use_kw:
# pass kW to MW
data.S[ii] /= 1000.0
data.I[ii] /= 1000.0
data.Y[ii] /= 1000.0
data.cost[ii] /= 1000.0
# reactive power sharing data
if data.active[ii]:
bus_data.q_fixed[i] -= data.S[ii].imag
bus_data.ii_fixed[i] -= data.I[ii].imag
bus_data.b_fixed[i] -= data.Y[ii].imag
# data.C_bus_elm[i, ii] = 1
ii += 1
for elm in circuit.get_static_generators():
if elm.bus is None:
data.bus_idx[ii] = -1
data.active[ii] = False
else:
i = bus_dict[elm.bus]
data.bus_idx[ii] = i
data.names[ii] = elm.name
data.idtag[ii] = elm.idtag
data.original_idx[ii] = ii
data.scalable[ii] = elm.scalable
data.is_static_generator[ii] = True
data.S[ii] -= elm.get_S_at(t_idx)
data.active[ii] = elm.get_active_at(t_idx)
data.cost[ii] = elm.get_Cost_at(t_idx)
data.shift_key[ii] = elm.get_shift_key_at(t_idx)
if elm.control_mode == StaticGeneratorControlMode.QVDroop and data.active[ii]:
if (not np.all(np.isfinite((elm.Snom, elm.droop, elm.Vset, elm.Vset_min, elm.Vset_max)))
or elm.Snom <= 0.0 or elm.droop <= 0.0
or elm.Vset_min <= 0.0 or elm.Vset_min >= elm.Vset_max):
raise ValueError('Static generator Q-V droop requires positive Snom/droop and valid voltage clamps: '
+ elm.name)
elif elm.bus.is_dc or not (elm.phA and elm.phB and elm.phC):
raise ValueError('Static generator Q-V droop requires an AC bus and all ABC phases: ' + elm.name)
else:
data.q_droop[ii] = elm.droop
data.q_droop_snom[ii] = elm.Snom / 1000.0 if elm.use_kw else elm.Snom
data.q_droop_vset[ii] = elm.Vset
data.q_droop_vmin[ii] = elm.Vset_min
data.q_droop_vmax[ii] = elm.Vset_max
else:
pass
# Controlled units inject I1 in the ABC formulation, not three fixed phase powers.
if fill_three_phase and data.active[ii] and data.q_droop[ii] == 0.0:
# Distribute missing P and Q independently, preserving explicit phase values.
phase_power: np.ndarray = np.array((elm.get_Sa_at(t_idx),
elm.get_Sb_at(t_idx),
elm.get_Sc_at(t_idx)), dtype=complex)
sequence_model: bool = (elm.conn == ShuntConnectionType.FloatingStar
or any((elm.R0, elm.X0, elm.R2, elm.X2)))
if sequence_model and not np.any(phase_power):
if elm.bus.is_dc or not (elm.phA and elm.phB and elm.phC):
raise ValueError('Static generator sequence model requires all AC phases: ' + elm.name)
else:
pass
z0: complex = complex(elm.R0, elm.X0)
z2: complex = complex(elm.R2, elm.X2)
if not np.isfinite(z0) or not np.isfinite(z2):
raise ValueError('Static generator Z0/Z2 must be finite: ' + elm.name)
else:
pass
y0: complex = 0j
if elm.conn == ShuntConnectionType.GroundedStar:
if abs(z0) < 1e-12:
raise ValueError('Grounded static generator needs nonzero Z0 (R0/X0): ' + elm.name)
else:
y0 = 1.0 / z0
elif elm.conn in (ShuntConnectionType.Delta, ShuntConnectionType.FloatingStar):
pass
else:
raise ValueError('Static generator sequence model does not support an explicit neutral: '
+ elm.name)
y2: complex = 1.0 / z2 if abs(z2) >= 1e-12 else 0j
# Keep the passive response in the existing ABC admittance storage.
# The positive sequence is a power source, never a passive shunt.
data.Y3_star[4 * ii + 1:4 * ii + 4, 1:4] = (
fortescue_012_to_abc(y0, 0j, y2) * circuit.Sbase / 3.0)
data.is_positive_sequence[ii] = True
else:
pass
if not sequence_model or np.any(phase_power):
# Explicit phase powers keep their original connection and profiles.
if not np.any(phase_power.real):
phase_power.real = elm.get_P_at(t_idx) / 3.0
else:
pass
if not np.any(phase_power.imag):
phase_power.imag = elm.get_Q_at(t_idx) / 3.0
else:
pass
if elm.conn == ShuntConnectionType.GroundedStar:
data.S3_star[4 * ii + 1:4 * ii + 4] -= phase_power
elif elm.conn == ShuntConnectionType.Delta:
data.S3_delta[4 * ii + 1:4 * ii + 4] -= phase_power
elif elm.conn == ShuntConnectionType.FloatingStar:
data.S3_floatingstar[4 * ii + 1:4 * ii + 4] -= phase_power
else:
raise ValueError(f'Unhandled static generator connection {elm.conn}: {elm.name}')
else:
pass
else:
pass
if elm.use_kw:
# pass kW to MW
data.S[ii] /= 1000.0
data.cost[ii] /= 1000.0
# reactive power sharing data
if data.active[ii]:
if data.q_droop[ii] > 0.0:
bus_data.q_fixed[i] -= data.S[ii].imag
else:
bus_data.q_fixed[i] += data.S[ii].imag
# bus_data.ii_fixed[i] += data.I[ii].imag
# bus_data.b_fixed[i] += data.Y[ii].imag
# data.C_bus_elm[i, ii] = 1
ii += 1
for elm in circuit.get_external_grids():
if elm.bus is None:
data.bus_idx[ii] = -1
data.active[ii] = False
else:
i = bus_dict[elm.bus]
data.bus_idx[ii] = i
data.names[ii] = elm.name
data.idtag[ii] = elm.idtag
data.scalable[ii] = elm.scalable
data.original_idx[ii] = ii
# change stuff depending on the modes
if elm.mode == ExternalGridMode.VD:
# bus_data.bus_types[i] = BusMode.Slack_tpe.value # set as Slack
bus_data.set_bus_mode(i, BusMode.Slack_tpe)
set_bus_control_voltage(i=i,
j=-1,
remote_control=False,
bus_name=elm.bus.name,
bus_data=bus_data,
bus_voltage_used=bus_voltage_used,
candidate_Vm=elm.get_Vm_at(t_idx),
use_stored_guess=use_stored_guess,
logger=logger)
elif elm.mode == ExternalGridMode.PV:
set_bus_control_voltage(i=i,
j=-1,
remote_control=False,
bus_name=elm.bus.name,
bus_data=bus_data,
bus_voltage_used=bus_voltage_used,
candidate_Vm=elm.get_Vm_at(t_idx),
use_stored_guess=use_stored_guess,
logger=logger)
data.S[ii] += elm.get_S_at(t_idx)
if fill_three_phase:
if elm.conn == ShuntConnectionType.GroundedStar:
data.S3_star[3 * ii + 1] += elm.get_Sa_at(t_idx)
data.S3_star[3 * ii + 2] += elm.get_Sb_at(t_idx)
data.S3_star[3 * ii + 3] += elm.get_Sc_at(t_idx)
elif elm.conn == ShuntConnectionType.Delta:
data.S3_delta[3 * ii + 1] += elm.get_Sa_at(t_idx)
data.S3_delta[3 * ii + 2] += elm.get_Sb_at(t_idx)
data.S3_delta[3 * ii + 3] += elm.get_Sc_at(t_idx)
else:
raise Exception(f"Unhandled connection type {elm.conn}")
data.active[ii] = elm.get_active_at(t_idx)
data.shift_key[ii] = elm.get_shift_key_at(t_idx)
if elm.use_kw:
# pass kW to MW
data.S[ii] /= 1000.0
data.cost[ii] /= 1000.0
# reactive power sharing data
if data.active[ii]:
bus_data.q_fixed[i] += data.S[ii].imag
bus_data.ii_fixed[i] += data.I[ii].imag
bus_data.b_fixed[i] += data.Y[ii].imag
# data.C_bus_elm[i, ii] = 1
ii += 1
for elm in circuit.get_current_injections():
if elm.bus is None:
data.bus_idx[ii] = -1
data.active[ii] = False
else:
i = bus_dict[elm.bus]
data.bus_idx[ii] = i
data.names[ii] = elm.name
data.idtag[ii] = elm.idtag
data.original_idx[ii] = ii
data.mttf[ii] = elm.mttf
data.mttr[ii] = elm.mttr
data.scalable[ii] = elm.scalable
data.I[ii] += elm.get_I_at(t_idx)
if fill_three_phase:
if elm.conn == ShuntConnectionType.GroundedStar:
data.I3_star[3 * ii + 1] += np.conj(elm.get_I1_at(t_idx))
data.I3_star[3 * ii + 2] += np.conj(elm.get_I2_at(t_idx))
data.I3_star[3 * ii + 3] += np.conj(elm.get_I3_at(t_idx))
elif elm.conn == ShuntConnectionType.Delta:
data.I3_delta[3 * ii + 1] += np.conj(elm.get_I1_at(t_idx))
data.I3_delta[3 * ii + 2] += np.conj(elm.get_I2_at(t_idx))
data.I3_delta[3 * ii + 3] += np.conj(elm.get_I3_at(t_idx))
else:
raise Exception(f"Unhandled connection type {elm.conn}")
data.active[ii] = elm.get_active_at(t_idx)
data.cost[ii] = elm.get_Cost_at(t_idx)
data.shift_key[ii] = elm.get_shift_key_at(t_idx)
if elm.use_kw:
# pass kW to MW
data.I[ii] /= 1000.0
data.cost[ii] /= 1000.0
# reactive power sharing data
if data.active[ii]:
bus_data.q_fixed[i] += data.S[ii].imag
bus_data.ii_fixed[i] += data.I[ii].imag
bus_data.b_fixed[i] += data.Y[ii].imag
# data.C_bus_elm[i, ii] = 1
ii += 1
return data
[docs]
def get_shunt_data(
data: ShuntData,
circuit: MultiCircuit,
bus_dict,
bus_voltage_used: BoolVec,
bus_data: BusData,
t_idx: int | None,
logger: Logger,
use_stored_guess: bool = False,
control_remote_voltage: bool = True,
fill_three_phase: bool = False
) -> None:
"""
:param data:
:param circuit:
:param bus_dict:
:param bus_voltage_used:
:param bus_data:
:param logger:
:param t_idx:
:param use_stored_guess:
:param control_remote_voltage:
:param fill_three_phase:
:return:
"""
ii = 0
for k, elm in enumerate(circuit.shunts):
if elm.bus is None:
data.bus_idx[k] = -1
data.active[k] = False
else:
i = bus_dict[elm.bus]
data.bus_idx[k] = i
data.names[k] = elm.name
data.idtag[k] = elm.idtag
data.original_idx[ii] = ii
data.mttf[k] = elm.mttf
data.mttr[k] = elm.mttr
data.active[k] = elm.get_active_at(t_idx)
data.grounds_neutral[k] = elm.phN and elm.conn == ShuntConnectionType.GroundedStar
data.conn[k] = elm.conn.idx()
data.Y[k] = elm.get_Y_at(t_idx)
if fill_three_phase:
if elm.conn == ShuntConnectionType.GroundedStar:
Y_abc = any([elm.get_Ya_at(t_idx), elm.get_Yb_at(t_idx), elm.get_Yc_at(t_idx)])
if not Y_abc:
data.Y3_star[4 * ii + 1, 1] = elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 2, 2] = elm.get_Y_at(t_idx) / 3
data.Y3_star[4 * ii + 3, 3] = elm.get_Y_at(t_idx) / 3
else:
data.Y3_star[4 * ii + 1, 1] = elm.get_Ya_at(t_idx)
data.Y3_star[4 * ii + 2, 2] = elm.get_Yb_at(t_idx)
data.Y3_star[4 * ii + 3, 3] = elm.get_Yc_at(t_idx)
elif (elm.conn == ShuntConnectionType.FloatingStar
or (elm.conn == ShuntConnectionType.NeutralStar and not elm.phN)):
# Admittances
Ya = elm.get_Ya_at(t_idx)
Yb = elm.get_Yb_at(t_idx)
Yc = elm.get_Yc_at(t_idx)
Ysum = Ya + Yb + Yc
if Ysum != 0.0 + 0.0j:
data.A_floating_star[ii] = Ya / Ysum
data.B_floating_star[ii] = Yb / Ysum
data.C_floating_star[ii] = Yc / Ysum
A = Ya / Ysum
B = Yb / Ysum
C = Yc / Ysum
# First row
data.Y3_star[4 * ii + 1, 1] = (1 - A) * Ya
data.Y3_star[4 * ii + 1, 2] = -B * Ya
data.Y3_star[4 * ii + 1, 3] = -C * Ya
# Second row
data.Y3_star[4 * ii + 2, 1] = -A * Yb
data.Y3_star[4 * ii + 2, 2] = (1 - B) * Yb
data.Y3_star[4 * ii + 2, 3] = -C * Yb
# Third row
data.Y3_star[4 * ii + 3, 1] = -A * Yc
data.Y3_star[4 * ii + 3, 2] = -B * Yc
data.Y3_star[4 * ii + 3, 3] = (1 - C) * Yc
elif elm.conn == ShuntConnectionType.NeutralStar:
# Admittance
Ya = elm.get_Ya_at(t_idx)
Yb = elm.get_Yb_at(t_idx)
Yc = elm.get_Yc_at(t_idx)
# First row
data.Y3_star[4 * ii + 0, 0] = Ya + Yb + Yc + 1e-10j
data.Y3_star[4 * ii + 0, 1] = -Ya
data.Y3_star[4 * ii + 0, 2] = -Yb
data.Y3_star[4 * ii + 0, 3] = -Yc
# Second row
data.Y3_star[4 * ii + 1, 0] = -Ya
data.Y3_star[4 * ii + 1, 1] = Ya
# Third row
data.Y3_star[4 * ii + 2, 0] = -Yb
data.Y3_star[4 * ii + 2, 2] = Yb
# Fourth row
data.Y3_star[4 * ii + 3, 0] = -Yc
data.Y3_star[4 * ii + 3, 3] = Yc
elif elm.conn == ShuntConnectionType.Delta:
data.Y3_star[4 * ii:4 * ii + 4, [0, 1, 2, 3]] = delta2StarAdmittance(
Yab=elm.get_Ya_at(t_idx),
Ybc=elm.get_Yb_at(t_idx),
Yca=elm.get_Yc_at(t_idx)
)
else:
raise Exception(f"Unhandled connection type {elm.conn}")
if elm.use_kw:
# pass kW to MW
data.Y[ii] /= 1000.0
# reactive power sharing data
if data.active[ii]:
bus_data.b_fixed[i] += data.Y[ii].imag
# data.C_bus_elm[i, k] = 1
ii += 1
for elm in circuit.controllable_shunts:
if elm.bus is None:
data.bus_idx[ii] = -1
data.active[ii] = False
else:
i = bus_dict[elm.bus]
data.bus_idx[ii] = i
data.names[ii] = elm.name
data.idtag[ii] = elm.idtag
data.original_idx[ii] = ii
data.mttf[ii] = elm.mttf
data.mttr[ii] = elm.mttr
data.control_mode_int[ii] = elm.control_mode.idx()
data.conn[ii] = elm.conn.idx()
data.vset[ii] = elm.get_Vset_at(t_idx)
data.vmin[ii] = elm.Vmin
data.vmax[ii] = elm.Vmax
if elm.control_mode == ShuntControlMode.Continuous:
data.qmin[ii] = -elm.Bmax
data.qmax[ii] = -elm.Bmin
else:
data.qmin[ii] = elm.Bmin
data.qmax[ii] = elm.Bmax
data.step[ii] = elm.step
data.g_steps.insert(i=ii, x=np.insert(np.cumsum(elm.g_steps), 0, 0))
data.b_steps.insert(i=ii, x=np.insert(np.cumsum(elm.b_steps), 0, 0))
data.active[ii] = elm.get_active_at(t_idx)
data.cost[ii] = elm.get_Cost_at(t_idx)
if elm.control_mode == ShuntControlMode.Locked:
data.Y[ii] += elm.get_Y_at(t_idx)
if elm.control_mode == ShuntControlMode.Continuous:
data.Y[ii] += elm.get_Y_at(t_idx)
if elm.control_mode == ShuntControlMode.Discrete:
# Base injection at the current step, using the same 0-prepended
# cumulative ladder as data.b_steps/data.g_steps and the discrete
# controller (step 0 = neutral/off, step k = first k blocks on).
cum_b = np.insert(np.cumsum(elm.b_steps), 0, 0.0)
cum_g = np.insert(np.cumsum(elm.g_steps), 0, 0.0)
s = elm.step if 0 <= elm.step < len(cum_b) else 0
data.Y[ii] += complex(cum_g[s], cum_b[s])
if fill_three_phase:
if elm.control_mode == ShuntControlMode.Continuous:
# U1 control solves a common susceptance in the existing controller.
# Keep only conductance here, avoiding a second fixed B contribution.
if elm.conn == ShuntConnectionType.GroundedStar:
pattern: np.ndarray = np.eye(3, dtype=complex)
elif elm.conn in (ShuntConnectionType.Delta, ShuntConnectionType.FloatingStar):
pattern = fortescue_012_to_abc(0j, 1+0j, 1+0j)
else:
raise ValueError('Continuous shunt U1 control does not support an explicit neutral: '
+ elm.name)
admittance: complex = complex(data.Y[ii].real)
if bus_data.bus_types[i] == BusMode.Slack_tpe.value:
# The ideal slack supplies voltage control; retain this shunt's fixed step.
admittance = data.Y[ii]
else:
pass
if elm.use_kw:
admittance /= 1000.0
else:
pass
data.Y3_star[4 * ii + 1:4 * ii + 4, 1:4] = (
pattern * admittance * data.active[ii] / 3.0)
data.qmin[ii] /= 1000.0 if elm.use_kw else 1.0
data.qmax[ii] /= 1000.0 if elm.use_kw else 1.0
elif elm.conn == ShuntConnectionType.GroundedStar:
data.Y3_star[3 * ii + 0, 1] = elm.get_Ya_at(t_idx)
data.Y3_star[3 * ii + 1, 2] = elm.get_Yb_at(t_idx)
data.Y3_star[3 * ii + 2, 3] = elm.get_Yc_at(t_idx)
elif elm.conn == ShuntConnectionType.Delta:
data.Y3_star[4 * ii:4 * ii + 4, [0, 1, 2, 3]] = delta2StarAdmittance(
Yab=elm.get_Ya_at(t_idx),
Ybc=elm.get_Yb_at(t_idx),
Yca=elm.get_Yc_at(t_idx)
)
else:
raise Exception(f"Unhandled connection type {elm.conn}")
if elm.control_mode == ShuntControlMode.Continuous and data.active[ii]:
if elm.control_bus is not None:
remote_control = True
j = bus_dict[elm.control_bus]
else:
remote_control = False
j = -1
data.controllable_bus_idx[ii] = j
set_bus_control_voltage(i=i,
j=j,
remote_control=remote_control and control_remote_voltage,
bus_name=elm.bus.name,
bus_data=bus_data,
bus_voltage_used=bus_voltage_used,
candidate_Vm=elm.get_Vset_at(t_idx),
use_stored_guess=use_stored_guess,
logger=logger)
if elm.use_kw:
# pass kW to MW
data.Y[ii] /= 1000.0
# reactive power sharing data
if data.active[ii]:
if data.control_mode_int[ii] == ShuntControlMode.Locked.idx():
bus_data.q_shared_total[i] += data.Y[ii].imag
data.q_share[ii] = data.Y[ii].imag
else:
bus_data.b_fixed[i] += data.Y[ii].imag
# data.C_bus_elm[i, ii] = 1
ii += 1
[docs]
def fill_generator_parent(
k: int,
data: GeneratorData | BatteryData,
elm: dev.Generator | dev.Battery,
bus_dict: Dict[dev.Bus, int],
bus_voltage_used: BoolVec,
logger: Logger,
bus_data: BusData,
t_idx: int | None = None,
use_stored_guess: bool = False,
control_remote_voltage: bool = True,
fill_three_phase: bool = False
) -> None:
"""
Fill the common ancestor of generation and batteries
:param k:
:param data:
:param elm:
:param bus_dict:
:param bus_voltage_used:
:param logger:
:param bus_data:
:param t_idx:
:param use_stored_guess:
:param control_remote_voltage:
:param fill_three_phase:
:return:
"""
if elm.bus is None:
data.bus_idx[k] = -1
data.active[k] = False
return
idx3 = np.arange(3)
i = bus_dict[elm.bus]
data.bus_idx[k] = i
data.names[k] = elm.name
data.idtag[k] = elm.idtag
data.original_idx[k] = k
data.mttf[k] = elm.mttf
data.mttr[k] = elm.mttr
control_mode: GeneratorControlMode = elm.get_control_mode_prof_at(t_idx)
data.control_mode_int[k] = control_mode.idx()
data.conn[k] = elm.conn.idx()
data.installed_p[k] = elm.Snom
bus_data.installed_power[i] += elm.Snom
# r0, r1, r2, x0, x1, x2
data.r0[k] = elm.R0
data.r1[k] = elm.R1
data.r2[k] = elm.R2
data.x0[k] = elm.X0
data.x1[k] = elm.X1
data.x2[k] = elm.X2
# asynchronous generator impedance
data.Rs[k] = elm.Rs
data.Xs[k] = elm.Xs
data.Xm[k] = elm.Xm
data.Rr[k] = elm.Rr
data.Xr[k] = elm.Xr
data.tpe_int[k] = elm.tpe.idx()
data.startup_cost[k] = elm.startup_cost
data.shut_down_cost[k] = elm.shutdown_cost
data.ramp_up[k] = elm.ramp_up
data.ramp_down[k] = elm.ramp_down
data.min_time_up[k] = elm.min_time_up
data.min_time_down[k] = elm.min_time_down
data.dispatchable[k] = elm.get_enabled_dispatch_at(t_idx)
data.must_run[k] = elm.get_must_run_at(t_idx)
data.capex[k] = elm.capex
data.snom[k] = elm.Snom
data.scalable[k] = elm.scalable
data.p[k] = elm.get_P_at(t_idx)
data.active[k] = elm.get_active_at(t_idx)
if hasattr(data, 'is_static_generator'):
data.is_static_generator[k] = elm.is_static_generator
data.v[k] = elm.get_Vset_at(t_idx)
data.k_droop[k] = elm.k_droop
data.dead_band[k] = elm.dead_band
pmin, pmax = normalize_upper_bound(
lower=elm.get_Pmin_at(t_idx),
upper=elm.get_Pmax_at(t_idx),
logger=logger,
device_name=elm.name,
device_class=str(elm.device_type.value),
lower_name="Pmin",
upper_name="Pmax",
)
data.pmax[k] = pmax
data.pmin[k] = pmin
if elm.use_reactive_power_curve:
data.qmin[k] = elm.q_curve.get_qmin(data.p[k])
data.qmax[k] = elm.q_curve.get_qmax(data.p[k])
else:
data.qmin[k] = elm.get_Qmin_at(t_idx)
data.qmax[k] = elm.get_Qmax_at(t_idx)
data.cost_0[k] = elm.get_Cost0_at(t_idx)
data.cost_1[k] = elm.get_Cost_at(t_idx)
data.cost_2[k] = elm.get_Cost2_at(t_idx)
data.shift_key[k] = elm.get_shift_key_at(t_idx)
if data.active[k]:
if elm.get_srap_enabled_at(t_idx) and data.p[k] > 0.0:
bus_data.srap_available_power[i] += data.p[k]
if control_mode == GeneratorControlMode.V:
if elm.control_bus is not None:
remote_control = True
j = bus_dict[elm.control_bus]
else:
remote_control = False
j = -1
data.controllable_bus_idx[k] = j
set_bus_control_voltage(i=i,
j=j,
remote_control=remote_control and control_remote_voltage,
bus_name=elm.bus.name,
bus_data=bus_data,
bus_voltage_used=bus_voltage_used,
candidate_Vm=elm.get_Vset_at(t_idx),
use_stored_guess=use_stored_guess,
logger=logger)
data.q[k] = 0.0
elif control_mode == GeneratorControlMode.Q:
data.q[k] = elm.get_Q_at(t_idx)
elif control_mode == GeneratorControlMode.QVDroop:
# Q will be computed by the droop
data.q[k] = 0.0
else:
pass
if elm.use_kw:
# pass kW to MW
data.p[k] /= 1000.0
data.pmax[k] /= 1000.0
data.pmin[k] /= 1000.0
data.qmax[k] /= 1000.0
data.qmin[k] /= 1000.0
data.snom[k] /= 1000.0
# data.cost_0[k] /= 1000.0
data.cost_1[k] /= 1000.0
data.cost_2[k] /= 1e6 # this is because of MW^2
if fill_three_phase:
# Note: for a generator that is balanced, the delta and star configurations
# translate to the same values in star
data.p3_star[3 * k + idx3] = data.p[k] / 3.0
# reactive power-sharing data
# We use P as a reference for scaling, hence issues may arise if P = 0.0
# Thus we add a small value to compensate for that
# The small value cannot be 1e-20, as then the split of Q
# would be half the value (1e-20/1e-20).
# A value of 1e-14 seems a sweet compromise.
if data.active[k]:
if data.control_mode_int[k] == GeneratorControlMode.V.idx():
bus_data.q_shared_total[i] += data.p[k] + 1e-14
data.q_share[k] = data.p[k] + 1e-14
# bus_data.q_shared_total[i] += data.p[k]
# data.q_share[k] = data.p[k]
else:
bus_data.q_fixed[i] += data.get_q_at(k)
[docs]
def get_generator_data(
data: GeneratorData,
circuit: MultiCircuit,
bus_dict,
bus_voltage_used: BoolVec,
logger: Logger,
bus_data: BusData,
t_idx: int | None,
opf_results: VALID_OPF_RESULTS | None = None,
time_series: bool = False,
use_stored_guess: bool = False,
control_remote_voltage: bool = True,
fill_three_phase: bool = False
) -> Dict[str, int]:
"""
:param data:
:param circuit:
:param bus_dict:
:param bus_voltage_used:
:param logger:
:param bus_data:
:param opf_results:
:param t_idx:
:param time_series:
:param use_stored_guess:
:param control_remote_voltage:
:param fill_three_phase:
:return:
"""
gen_index_dict: Dict[str, int] = dict()
for k, elm in enumerate(circuit.get_generators()):
gen_index_dict[elm.idtag] = k # associate the idtag to the index
fill_generator_parent(k=k,
elm=elm,
data=data,
bus_data=bus_data,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
logger=logger,
t_idx=t_idx,
use_stored_guess=use_stored_guess,
control_remote_voltage=control_remote_voltage,
fill_three_phase=fill_three_phase)
if opf_results is not None:
# overwrite P with the OPF results
if time_series:
data.p[k] = opf_results.generator_power[t_idx, k] - opf_results.generator_shedding[t_idx, k]
else:
data.p[k] = opf_results.generator_power[k] - opf_results.generator_shedding[k]
return gen_index_dict
[docs]
def get_battery_data(
data: BatteryData,
circuit: MultiCircuit,
bus_dict: Dict[Bus, int],
bus_voltage_used: BoolVec,
logger: Logger,
bus_data: BusData,
t_idx: int | None,
opf_results: VALID_OPF_RESULTS | None = None,
time_series=False,
control_remote_voltage: bool = True,
fill_three_phase: bool = False
) -> None:
"""
:param data:
:param circuit:
:param bus_dict:
:param bus_voltage_used:
:param logger:
:param bus_data:
:param opf_results:
:param t_idx:
:param time_series:
:param control_remote_voltage:
:param fill_three_phase:
:return:
"""
for k, elm in enumerate(circuit.get_batteries()):
fill_generator_parent(k=k,
elm=elm,
data=data,
bus_data=bus_data,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
logger=logger,
t_idx=t_idx,
control_remote_voltage=control_remote_voltage,
fill_three_phase=fill_three_phase)
data.enom[k] = elm.Enom
min_soc, max_soc = normalize_upper_bound(
lower=elm.min_soc,
upper=elm.max_soc,
logger=logger,
device_name=elm.name,
device_class=str(elm.device_type.value),
lower_name="min_soc",
upper_name="max_soc",
)
data.min_soc[k] = min_soc
data.max_soc[k] = max_soc
data.soc_0[k] = elm.soc_0
e_min, e_max = normalize_upper_bound(
lower=elm.Enom * data.min_soc[k],
upper=elm.Enom * data.max_soc[k],
logger=logger,
device_name=elm.name,
device_class=str(elm.device_type.value),
lower_name="Emin",
upper_name="Emax",
)
data.e_min[k] = e_min
data.e_max[k] = e_max
data.discharge_efficiency[k] = elm.discharge_efficiency
data.charge_efficiency[k] = elm.charge_efficiency
if opf_results is not None:
# overwrite P with the OPF results
if time_series:
data.p[k] = opf_results.battery_power[t_idx, k]
else:
data.p[k] = opf_results.battery_power[k]
[docs]
def fill_parent_branch(i: int,
elm: BRANCH_TYPES,
data: PassiveBranchData,
bus_data: BusData,
bus_dict: Dict[Bus, int],
bus_voltage_used: BoolVec,
use_stored_guess=False,
t_idx: int | None = None, ):
"""
:param i:
:param elm:
:param data:
:param bus_data:
:param bus_dict:
:param bus_voltage_used:
:param use_stored_guess:
:param t_idx:
:return:
"""
data.names[i] = elm.name
data.idtag[i] = elm.idtag
data.mttf[i] = elm.mttf
data.mttr[i] = elm.mttr
data.active[i] = elm.get_active_at(t_idx)
data.rates[i] = elm.get_rate_at(t_idx)
data.contingency_rates[i] = data.rates[i] * elm.get_contingency_factor_at(t_idx)
data.protection_rates[i] = data.rates[i] * elm.get_protection_rating_factor_at(t_idx)
data.overload_cost[i] = elm.get_Cost_at(t_idx)
f = bus_dict[elm.bus_from]
t = bus_dict[elm.bus_to]
data.F[i] = f
data.T[i] = t
data.original_idx[i] = i
data.reducible[i] = int(elm.reducible)
data.contingency_enabled[i] = int(elm.contingency_enabled)
data.monitor_loading[i] = int(elm.monitor_loading)
data.virtual_tap_f[i], data.virtual_tap_t[i] = elm.get_virtual_taps()
# This is to initialize the bus voltages for branches
# that do have a significant virtual tap difference.
# i.e. transformers for distribution systems
# Grounded buses carry a pinned ground-reference Vbus from get_bus_data
# and must not be overwritten by the virtual-tap default.
if not bus_voltage_used[f] and not use_stored_guess and not bus_data.is_grounded[f]:
bus_data.Vbus[f] = data.virtual_tap_f[i]
if not bus_voltage_used[t] and not use_stored_guess and not bus_data.is_grounded[t]:
bus_data.Vbus[t] = data.virtual_tap_t[i]
return f, t
[docs]
def fill_controllable_branch(
ii: int,
elm: Union[dev.Transformer2W, dev.Winding, dev.UPFC],
data: PassiveBranchData,
ctrl_data: ActiveBranchData,
bus_data: BusData,
bus_dict: Dict[Bus, int],
t_idx: int | None,
opf_results: VALID_OPF_RESULTS | None,
use_stored_guess: bool,
bus_voltage_used: BoolVec,
Sbase: float,
control_taps_modules: bool,
control_taps_phase: bool,
logger: Logger):
"""
:param ii:
:param elm:
:param data:
:param ctrl_data:
:param bus_data:
:param bus_dict:
:param t_idx:
:param opf_results:
:param use_stored_guess:
:param bus_voltage_used:
:param Sbase:
:param control_taps_modules:
:param control_taps_phase:
:param logger:
:return:
"""
fill_parent_branch(i=ii,
elm=elm,
data=data,
bus_data=bus_data,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
use_stored_guess=use_stored_guess,
t_idx=t_idx)
if control_taps_phase:
ctrl_data.tap_phase_control_mode[ii] = elm.get_tap_phase_control_mode_at(t_idx).idx()
if control_taps_modules:
ctrl_data.tap_module_control_mode[ii] = elm.get_tap_module_control_mode_at(t_idx).idx()
if elm.regulation_bus is None:
reg_bus = elm.bus_from
if ctrl_data.tap_module_control_mode[ii] == TapModuleControl.Vm.idx():
logger.add_warning("Unspecified regulation bus",
device_class=elm.device_type.value,
device=elm.name)
else:
reg_bus = elm.regulation_bus
ctrl_data.tap_controlled_buses[ii] = bus_dict[reg_bus]
ctrl_data.Pset[ii] = elm.get_Pset_at(t_idx) / Sbase
ctrl_data.Qset[ii] = elm.get_Qset_at(t_idx) / Sbase
ctrl_data.vset[ii] = elm.get_vset_at(t_idx)
if opf_results is not None:
if opf_results.tap_angle.ndim == 1:
ctrl_data.tap_angle[ii] = opf_results.tap_angle[ii]
else:
if t_idx is None:
ctrl_data.tap_angle[ii] = opf_results.tap_angle[0, ii]
else:
ctrl_data.tap_angle[ii] = opf_results.tap_angle[t_idx, ii]
ctrl_data.tap_module[ii] = elm.get_tap_module_at(t_idx)
ctrl_data.tap_phase_control_mode[ii] = TapPhaseControl.fixed.idx()
ctrl_data.tap_module_control_mode[ii] = TapModuleControl.fixed.idx()
else:
ctrl_data.tap_angle[ii] = elm.get_tap_phase_at(t_idx)
ctrl_data.tap_module[ii] = elm.get_tap_module_at(t_idx)
ctrl_data.is_controlled[ii] = 1
tap_module_min, tap_module_max = normalize_upper_bound(
lower=elm.tap_module_min,
upper=elm.tap_module_max,
logger=logger,
device_name=elm.name,
device_class=str(elm.device_type.value),
lower_name="tap_module_min",
upper_name="tap_module_max",
)
ctrl_data.tap_module_min[ii] = tap_module_min
ctrl_data.tap_module_max[ii] = tap_module_max
tap_angle_min, tap_angle_max = normalize_upper_bound(
lower=elm.tap_phase_min,
upper=elm.tap_phase_max,
logger=logger,
device_name=elm.name,
device_class=str(elm.device_type.value),
lower_name="tap_angle_min",
upper_name="tap_angle_max",
)
ctrl_data.tap_angle_min[ii] = tap_angle_min
ctrl_data.tap_angle_max[ii] = tap_angle_max
if ctrl_data.tap_module_control_mode[ii] != TapModuleControl.fixed.idx():
ctrl_data.any_pf_control = True
if not ctrl_data.any_pf_control: # if true, we can skip this step
if ctrl_data.tap_phase_control_mode[ii] != TapPhaseControl.fixed.idx():
ctrl_data.any_pf_control = True
if not use_stored_guess:
if ctrl_data.tap_module_control_mode[ii] == TapModuleControl.Vm.idx():
ctrl_data.any_pf_control = True
bus_idx = ctrl_data.tap_controlled_buses[ii]
if not bus_voltage_used[bus_idx]:
if elm.vset > 0.0:
bus_data.Vbus[bus_idx] = elm.vset
else:
logger.add_warning("Branch control voltage out of bounds",
device_class=str(elm.device_type.value),
device=elm.name,
value=elm.vset)
elif elm.vset != bus_data.Vbus[bus_idx]:
logger.add_error(msg='Different control voltage set points',
device=bus_data.names[bus_idx],
value=elm.vset,
expected_value=bus_data.Vbus[bus_idx])
# modify the voltage angle guess using the phase
if ctrl_data.tap_angle[ii] != 0:
f = bus_dict[elm.bus_from]
t = bus_dict[elm.bus_to]
Vm = abs(bus_data.Vbus[f])
Va = np.angle(bus_data.Vbus[f], deg=False)
bus_data.Vbus[f] = Vm * np.exp(1j * (Va + ctrl_data.tap_angle[ii]))
[docs]
def get_branch_data(
data: PassiveBranchData,
ctrl_data: ActiveBranchData,
circuit: MultiCircuit,
bus_dict: Dict[Bus, int],
bus_data: BusData,
bus_voltage_used: BoolVec,
apply_temperature: bool,
branch_tolerance_mode: BranchImpedanceMode,
t_idx: int | None,
opf_results: VALID_OPF_RESULTS | None = None,
use_stored_guess: bool = False,
control_taps_modules: bool = True,
control_taps_phase: bool = True,
logger: Logger = Logger(),
fill_three_phase: bool = False
) -> Dict[BRANCH_TYPES, int]:
"""
Compile BranchData for a time step or the snapshot
:param data: BranchData
:param ctrl_data: ControllableBranchData
:param circuit: MultiCircuit
:param bus_dict: Dictionary of buses to compute the indices
:param bus_data: BusData
:param bus_voltage_used:
:param apply_temperature: apply the temperature correction?
:param branch_tolerance_mode: BranchImpedanceMode
:param t_idx: time index (-1 is useless)
:param opf_results: OptimalPowerFlowResults
:param use_stored_guess: use the stored voltage ?
:param control_taps_modules: Control TapsModules
:param control_taps_phase: Control TapsPhase
:param logger: Logger
:param fill_three_phase: Fill the tree phase info?
:return: BranchData
"""
branch_dict: Dict[BRANCH_TYPES, int] = dict()
idx4 = np.array(range(4))
ii = 0
# Compile the lines
for i, elm in enumerate(circuit.lines):
# generic stuff
fill_parent_branch(i=ii,
elm=elm,
data=data,
bus_data=bus_data,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
use_stored_guess=use_stored_guess,
t_idx=t_idx)
data.R[ii] = elm.R_corrected if apply_temperature else elm.R
if branch_tolerance_mode == BranchImpedanceMode.Lower:
data.R[ii] *= (1 - elm.tolerance / 100.0)
elif branch_tolerance_mode == BranchImpedanceMode.Upper:
data.R[ii] *= (1 + elm.tolerance / 100.0)
data.X[ii] = elm.X
data.B[ii] = elm.B
# Keep the physical line shunt in the existing sequence data owners.
data.G[ii] = elm.G
data.R0[ii] = elm.R0
data.X0[ii] = elm.X0
data.B0[ii] = elm.B0
data.G0[ii] = elm.G0
data.R2[ii] = elm.R2
data.X2[ii] = elm.X2
data.B2[ii] = elm.B2
if fill_three_phase:
"""
yff = ys_abc + ysh_abc / 2
yft = - ys_abc
ytf = - ys_abc
ytt = ys_abc + ysh_abc / 2
"""
k4 = 4 * ii + idx4
y1 = elm.ys.values + elm.ysh.values / 2.0 * 1e-6
y2 = - elm.ys.values
data.Yff3[k4, :] = y1
data.Yft3[k4, :] = y2
data.Ytf3[k4, :] = y2
data.Ytt3[k4, :] = y1
""" Save the phases of each line """
data.phN[ii] = elm.ys.phN
data.phA[ii] = elm.ys.phA
data.phB[ii] = elm.ys.phB
data.phC[ii] = elm.ys.phC
# store for later
branch_dict[elm] = ii
# Physical line templates are defined by their phase matrices. A single-phase
# tower or cable can have zero sequence scalars without being an ideal link.
is_physical_line: bool = isinstance(
elm.template,
(dev.OverheadLineType, dev.UndergroundLineType),
)
if is_physical_line:
pass
else:
data.detect_superconductor_at(ii)
ii += 1
# DC-lines
for i, elm in enumerate(circuit.dc_lines):
# generic stuff
fill_parent_branch(i=ii,
elm=elm,
data=data,
bus_data=bus_data,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
use_stored_guess=use_stored_guess,
t_idx=t_idx)
data.R[ii] = elm.R_corrected if apply_temperature else elm.R
if branch_tolerance_mode == BranchImpedanceMode.Lower:
data.R[ii] *= (1 - elm.tolerance / 100.0)
elif branch_tolerance_mode == BranchImpedanceMode.Upper:
data.R[ii] *= (1 + elm.tolerance / 100.0)
# store for later
branch_dict[elm] = ii
data.dc[ii] = 1
# handle """superconductor branches"""
data.detect_superconductor_at(ii)
ii += 1
# 2-winding transformers
for i, elm in enumerate(circuit.transformers2w):
fill_controllable_branch(ii=ii,
elm=elm,
data=data,
ctrl_data=ctrl_data,
bus_data=bus_data,
bus_dict=bus_dict,
t_idx=t_idx,
opf_results=opf_results,
use_stored_guess=use_stored_guess,
bus_voltage_used=bus_voltage_used,
Sbase=circuit.Sbase,
control_taps_modules=control_taps_modules,
control_taps_phase=control_taps_phase,
logger=logger)
data.R[ii] = elm.R_corrected if apply_temperature else elm.R
if branch_tolerance_mode == BranchImpedanceMode.Lower:
data.R[ii] *= (1 - elm.tolerance / 100.0)
elif branch_tolerance_mode == BranchImpedanceMode.Upper:
data.R[ii] *= (1 + elm.tolerance / 100.0)
data.X[ii] = elm.X
data.G[ii] = elm.G
data.B[ii] = elm.B
data.R0[ii] = elm.R0
data.X0[ii] = elm.X0
data.G0[ii] = elm.G0
data.B0[ii] = elm.B0
data.R2[ii] = elm.R2
data.X2[ii] = elm.X2
data.G2[ii] = elm.G2
data.B2[ii] = elm.B2
if fill_three_phase:
k4 = 4 * ii + idx4
(data.Yff3[k4, :],
data.Yft3[k4, :],
data.Ytf3[k4, :],
data.Ytt3[k4, :]) = elm.transformer_admittance(vtap_f=data.virtual_tap_f[ii],
vtap_t=data.virtual_tap_t[ii],
logger=logger)
(data.phN[ii],
data.phA[ii],
data.phB[ii],
data.phC[ii]) = elm.transformer_phases(logger=logger)
data.conn[ii] = elm.conn.idx()
data.conn_f[ii] = elm.conn_f.idx()
data.conn_t[ii] = elm.conn_t.idx()
data.m_taps[ii] = elm.tap_changer.tap_modules_array
data.tau_taps[ii] = elm.tap_changer.tap_angles_array
# store for later
branch_dict[elm] = ii
# handle """superconductor branches"""
data.detect_superconductor_at(ii)
ii += 1
# windings
for i, elm in enumerate(circuit.windings):
if elm.bus_from is not None and elm.bus_to is not None:
# generic stuff
fill_controllable_branch(ii=ii,
elm=elm,
data=data,
ctrl_data=ctrl_data,
bus_data=bus_data,
bus_dict=bus_dict,
t_idx=t_idx,
opf_results=opf_results,
use_stored_guess=use_stored_guess,
bus_voltage_used=bus_voltage_used,
Sbase=circuit.Sbase,
control_taps_modules=control_taps_modules,
control_taps_phase=control_taps_phase,
logger=logger)
data.R[ii] = elm.R_corrected if apply_temperature else elm.R
if branch_tolerance_mode == BranchImpedanceMode.Lower:
data.R[ii] *= (1 - elm.tolerance / 100.0)
elif branch_tolerance_mode == BranchImpedanceMode.Upper:
data.R[ii] *= (1 + elm.tolerance / 100.0)
data.X[ii] = elm.X
data.G[ii] = elm.G
data.B[ii] = elm.B
data.R0[ii] = elm.R0
data.X0[ii] = elm.X0
data.G0[ii] = elm.G0
data.B0[ii] = elm.B0
data.R2[ii] = elm.R2
data.X2[ii] = elm.X2
data.G2[ii] = elm.G2
data.B2[ii] = elm.B2
if fill_three_phase:
k4 = 4 * ii + idx4
(data.Yff3[k4, :], data.Yft3[k4, :],
data.Ytf3[k4, :], data.Ytt3[k4, :]) = elm.transformer_admittance(
vtap_f=data.virtual_tap_f[ii], vtap_t=data.virtual_tap_t[ii], logger=logger)
data.phN[ii], data.phA[ii], data.phB[ii], data.phC[ii] = elm.transformer_phases(logger)
else:
pass
data.conn[ii] = elm.conn.idx()
winding_conn_f: WindingType
winding_conn_t: WindingType
winding_conn_f, winding_conn_t = elm.get_winding_connections()
data.conn_f[ii] = winding_conn_f.idx()
data.conn_t[ii] = winding_conn_t.idx()
data.m_taps[ii] = elm.tap_changer.tap_modules_array
data.tau_taps[ii] = elm.tap_changer.tap_angles_array
# store for later
branch_dict[elm] = ii
# handle """superconductor branches"""
data.detect_superconductor_at(ii)
ii += 1
else:
logger.add_error("Ill connected winding", device=elm.idtag)
# UPFC
for i, elm in enumerate(circuit.upfc_devices):
# generic stuff
fill_controllable_branch(ii=ii,
elm=elm,
data=data,
ctrl_data=ctrl_data,
bus_data=bus_data,
bus_dict=bus_dict,
t_idx=t_idx,
opf_results=opf_results,
use_stored_guess=use_stored_guess,
bus_voltage_used=bus_voltage_used,
Sbase=circuit.Sbase,
control_taps_modules=control_taps_modules,
control_taps_phase=control_taps_phase,
logger=logger)
ysh1 = elm.get_ysh1()
data.R[ii] = elm.R
data.X[ii] = elm.X
data.G[ii] = ysh1.real
data.B[ii] = ysh1.imag
ysh0 = elm.get_ysh0()
data.R0[ii] = elm.R0
data.X0[ii] = elm.X0
data.G0[ii] = ysh0.real
data.B0[ii] = ysh0.imag
ysh2 = elm.get_ysh2()
data.R2[ii] = elm.R2
data.X2[ii] = elm.X2
data.G2[ii] = ysh2.real
data.B2[ii] = ysh2.imag
# store for later
branch_dict[elm] = ii
# handle """superconductor branches"""
data.detect_superconductor_at(ii)
ii += 1
# Series reactance
for i, elm in enumerate(circuit.series_reactances):
# generic stuff
fill_parent_branch(i=ii,
elm=elm,
data=data,
bus_data=bus_data,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
use_stored_guess=use_stored_guess,
t_idx=t_idx)
data.R[ii] = elm.R_corrected if apply_temperature else elm.R
if branch_tolerance_mode == BranchImpedanceMode.Lower:
data.R[ii] *= (1 - elm.tolerance / 100.0)
elif branch_tolerance_mode == BranchImpedanceMode.Upper:
data.R[ii] *= (1 + elm.tolerance / 100.0)
data.X[ii] = elm.X
data.R0[ii] = elm.R0
data.X0[ii] = elm.X0
data.R2[ii] = elm.R2
data.X2[ii] = elm.X2
if fill_three_phase:
# Reuse the sequence transformation; a reactor has no shunt branch.
# As for legacy lines, unspecified sequence data inherit Z1.
z1: complex = complex(data.R[ii], data.X[ii])
z0: complex = complex(data.R0[ii], data.X0[ii])
z2: complex = complex(data.R2[ii], data.X2[ii])
z0 = z0 if abs(z0) > 1e-10 else z1
z2 = z2 if abs(z2) > 1e-10 else z1
k4 = 4 * ii + idx4
ys: np.ndarray = np.zeros((4, 4), dtype=complex)
if abs(z1) > 0.0:
ys[1:, 1:] = fortescue_012_to_abc(1.0 / z0, 1.0 / z1, 1.0 / z2)
else:
# Ideal links are handled by the existing topology reduction.
pass
data.Yff3[k4, :] = ys
data.Yft3[k4, :] = -ys
data.Ytf3[k4, :] = -ys
data.Ytt3[k4, :] = ys
data.phA[ii] = data.phB[ii] = data.phC[ii] = True
else:
pass
# store for later
branch_dict[elm] = ii
# handle """superconductor branches"""
data.detect_superconductor_at(ii)
ii += 1
# Switches
for i, elm in enumerate(circuit.switch_devices):
# generic stuff
fill_parent_branch(i=ii,
elm=elm,
data=data,
bus_data=bus_data,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
use_stored_guess=use_stored_guess,
t_idx=t_idx)
if fill_three_phase:
data.phN[ii] = 1
data.phA[ii] = 1
data.phB[ii] = 1
data.phC[ii] = 1
data.R[ii] = elm.R
data.X[ii] = elm.X
# store for later
branch_dict[elm] = ii
# handle """superconductor branches"""
data.detect_superconductor_at(ii)
ii += 1
if fill_three_phase:
compile_line_couplings(circuit=circuit, data=data)
else:
pass
return branch_dict
[docs]
def compile_line_couplings(circuit: MultiCircuit, data: PassiveBranchData) -> None:
"""Stamp complete physical tower sections, including mutual circuit admittances.
:param circuit: Device model; only explicitly associated lines are coupled.
:param data: Compiled branches, with lines occupying the first rows.
:return: None.
"""
groups: dict[str, list[int]] = dict()
for k, line in enumerate(circuit.lines):
if line.coupling_group and data.active[k]:
groups.setdefault(line.coupling_group, list()).append(k)
else:
pass
mutual: lil_matrix = lil_matrix((8 * data.nelm, 8 * data.nelm), dtype=complex)
for name, indices in groups.items():
first: dev.Line = circuit.lines[indices[0]]
tower: dev.OverheadLineType
if not isinstance(first.template, dev.OverheadLineType):
raise ValueError(f"Line coupling {name}: an overhead tower template is required")
else:
tower = first.template
if not tower.is_computed():
tower.compute()
else:
pass
phases: IntVec = np.empty(3 * len(indices), dtype=int)
lengths: np.ndarray = np.empty(3 * len(indices))
for i, k in enumerate(indices):
line: dev.Line = circuit.lines[k]
if line.template is not tower:
raise ValueError(f"Line coupling {name}: circuits must share a template")
else:
pass
lengths[3 * i:3 * i + 3] = line.length
for p in range(3):
positions: IntVec = np.flatnonzero(tower.z_phases_abc == 3 * (line.circuit_idx - 1) + p + 1)
if len(positions) != 1:
raise ValueError(f"Line coupling {name}: each circuit must contain A, B and C")
else:
phases[3 * i + p] = positions[0]
if len(np.unique(phases)) != len(phases) or np.any(~np.isfinite(lengths) | (lengths <= 0)):
raise ValueError(f"Line coupling {name}: repeated circuit index or invalid section length")
else:
pass
# Use the existing earth-wire reduction. A guard wire is not a load neutral.
# Select active circuits before inversion: absent circuits carry no series current.
# Self blocks retain each circuit's length; mutual blocks span the shorter circuit.
section_lengths: np.ndarray = np.minimum.outer(lengths, lengths)
ys: np.ndarray = np.linalg.inv(tower.z_abc[np.ix_(phases, phases)] * section_lengths)
yh: np.ndarray = tower.y_abc[np.ix_(phases, phases)] * section_lengths
for i, k in enumerate(indices):
line = circuit.lines[k]
rows: IntVec = 4 * k + np.arange(1, 4)
block: slice = slice(3 * i, 3 * i + 3)
zbase: float = line.get_max_bus_nominal_voltage() ** 2 / circuit.Sbase
data.Yff3[4 * k:4 * k + 4, :] = 0.0
data.Yft3[4 * k:4 * k + 4, :] = 0.0
data.Ytf3[4 * k:4 * k + 4, :] = 0.0
data.Ytt3[4 * k:4 * k + 4, :] = 0.0
data.Yff3[rows, 1:4] = (ys[block, block] + yh[block, block] / 2) * zbase
data.Ytt3[rows, 1:4] = data.Yff3[rows, 1:4]
data.Yft3[rows, 1:4] = -ys[block, block] * zbase
data.Ytf3[rows, 1:4] = data.Yft3[rows, 1:4]
data.phN[k] = False
data.phA[k] = data.phB[k] = data.phC[k] = True
for j, peer in enumerate(indices):
if i != j:
other: dev.Line = circuit.lines[peer]
columns: IntVec = 4 * peer + np.arange(1, 4)
peer_block: slice = slice(3 * j, 3 * j + 3)
base: float = (line.get_max_bus_nominal_voltage() *
other.get_max_bus_nominal_voltage() / circuit.Sbase)
series: np.ndarray = ys[block, peer_block] * base
shunt: np.ndarray = yh[block, peer_block] * base / 2
# Reversed lines swap physical terminals, preserving their public from/to orientation.
f: IntVec = rows + (4 * data.nelm if line.coupling_reversed else 0)
t: IntVec = rows + (0 if line.coupling_reversed else 4 * data.nelm)
pf: IntVec = columns + (4 * data.nelm if other.coupling_reversed else 0)
pt: IntVec = columns + (0 if other.coupling_reversed else 4 * data.nelm)
mutual[np.ix_(f, pf)] = series + shunt
mutual[np.ix_(f, pt)] = -series
mutual[np.ix_(t, pf)] = -series
mutual[np.ix_(t, pt)] = series + shunt
else:
pass
data.Ycoupling3 = mutual.tocsc()
[docs]
def set_control_dev(k: int,
f: int,
t: int,
control_int: int,
control_dev: Bus | BRANCH_TYPES | None,
control_val: float,
control_bus_idx: IntVec,
control_branch_idx: IntVec,
bus_dict: Dict[Bus, int],
bus_data: BusData,
bus_voltage_used: BoolVec,
bus_angle_used: BoolVec,
use_stored_guess: bool,
logger: Logger):
"""
:param k: device index
:param f:
:param t:
:param control_int: ConverterControlType
:param control_dev: control device
:param control_val: control value
:param control_bus_idx: array to be filled in
:param control_branch_idx: array to be filled in
:param bus_dict: dictionary to be filled in
:param bus_data: bus data
:param bus_voltage_used: used bus voltage
:param bus_angle_used: used bus angle
:param use_stored_guess:
:param logger:
"""
if control_dev is not None:
if control_dev.device_type == DeviceType.BusDevice:
bus_idx = bus_dict[control_dev]
control_bus_idx[k] = bus_idx
if control_int == ConverterControlType.Vm_ac.idx():
set_bus_control_voltage_vsc(i=bus_idx,
j=-1,
remote_control=False,
bus_name=str(bus_data.names[bus_idx]),
bus_voltage_used=bus_voltage_used,
bus_data=bus_data,
candidate_Vm=control_val,
use_stored_guess=use_stored_guess,
logger=logger)
elif control_int == ConverterControlType.Vm_dc.idx():
set_bus_control_voltage_vsc(i=bus_idx,
j=-1,
remote_control=False,
bus_name=str(bus_data.names[bus_idx]),
bus_voltage_used=bus_voltage_used,
bus_data=bus_data,
candidate_Vm=control_val,
use_stored_guess=use_stored_guess,
logger=logger)
elif control_int == ConverterControlType.Va_ac.idx():
set_bus_control_angle_vsc(i=bus_idx,
j=-1,
remote_control=False,
bus_name=str(bus_data.names[bus_idx]),
bus_angle_used=bus_angle_used,
bus_data=bus_data,
candidate_Va=control_val,
use_stored_guess=use_stored_guess,
logger=logger)
else:
# TODO: the formulation does not allow for VSC remote control yet
# control_branch_idx[k] = branch_dict[control_dev]
control_branch_idx[k] = k
else:
if control_int == ConverterControlType.Vm_ac.idx():
control_bus_idx[k] = t
set_bus_control_voltage_vsc(i=t,
j=-1,
remote_control=False,
bus_name=str(bus_data.names[t]),
bus_voltage_used=bus_voltage_used,
bus_data=bus_data,
candidate_Vm=control_val,
use_stored_guess=use_stored_guess,
logger=logger)
elif control_int == ConverterControlType.Vm_dc.idx():
control_bus_idx[k] = f
set_bus_control_voltage_vsc(i=f,
j=-1,
remote_control=False,
bus_name=str(bus_data.names[f]),
bus_voltage_used=bus_voltage_used,
bus_data=bus_data,
candidate_Vm=control_val,
use_stored_guess=use_stored_guess,
logger=logger)
elif control_int == ConverterControlType.Va_ac.idx():
control_bus_idx[k] = t
set_bus_control_angle_vsc(i=t,
j=-1,
remote_control=False,
bus_name=str(bus_data.names[t]),
bus_angle_used=bus_angle_used,
bus_data=bus_data,
candidate_Va=control_val,
use_stored_guess=use_stored_guess,
logger=logger)
else:
# control_branch_idx[k] = len(branch_dict) + k # TODO: why?
control_branch_idx[k] = k
[docs]
def get_vsc_data(
data: VscData,
circuit: MultiCircuit,
bus_dict: Dict[Bus, int],
branch_dict: Dict[BRANCH_TYPES, int],
bus_data: BusData,
bus_voltage_used: BoolVec,
t_idx: int | None,
opf_results: VALID_OPF_RESULTS | None = None,
use_stored_guess: bool = False,
control_remote_voltage: bool = True,
logger: Logger = Logger()
) -> None:
"""
Compile VscData for a time step or the snapshot
:param data: VscData
:param circuit: MultiCircuit
:param bus_dict: Dictionary of buses to compute the indices
:param branch_dict: Dictionary of branches to compute the indices
:param bus_data: BusData
:param bus_voltage_used:
:param t_idx: time index (-1 is useless)
:param opf_results: OptimalPowerFlowResults
:param use_stored_guess: use the stored voltage ?
:param control_remote_voltage: Control RemoteVoltage
:param logger: Logger
:return: VscData
"""
bus_angle_used = np.array(bus_data.bus_types == BusMode.Slack_tpe.value).astype(bool)
ii = 0
# VSC
for i, elm in enumerate(circuit.vsc_devices):
# generic stuff
data.names[i] = elm.name
data.idtag[i] = elm.idtag
data.mttf[i] = elm.mttf
data.mttr[i] = elm.mttr
f = bus_dict[elm.bus_from]
t = bus_dict[elm.bus_to]
data.original_idx[i] = i
data.F[i] = f
# TODO SANPEN: Handle the -1 everywhere for this
data.F_dcn[i] = -1 if elm.bus_dc_n is None else bus_dict[elm.bus_dc_n]
data.T[i] = t
data.active[i] = elm.get_active_at(t_idx)
data.rates[i] = elm.get_rate_at(t_idx)
data.contingency_rates[i] = data.rates[i] * elm.get_contingency_factor_at(t_idx)
data.protection_rates[i] = data.rates[i] * elm.get_protection_rating_factor_at(t_idx)
data.overload_cost[i] = elm.get_Cost_at(t_idx)
data.control1_int[ii] = elm.get_control1_at(t_idx).idx()
data.control2_int[ii] = elm.get_control2_at(t_idx).idx()
data.fault_control_int[ii] = elm.get_fault_control_at(t_idx).idx()
data.control1_val[ii] = elm.get_control1_val_at(t_idx)
data.control2_val[ii] = elm.get_control2_val_at(t_idx)
data.control1_val_min[ii] = elm.control1_val_min
data.control1_val_max[ii] = elm.control1_val_max
data.control1_val_droop[ii] = elm.get_control1_val_droop_at(t_idx)
data.control1_droop_val[ii] = elm.get_control1_droop_val_at(t_idx)
data.control1_droop_val_min[ii] = elm.control1_droop_val_min
data.control1_droop_val_max[ii] = elm.control1_droop_val_max
data.control2_val_min[ii] = elm.control2_val_min
data.control2_val_max[ii] = elm.control2_val_max
data.control2_val_droop[ii] = elm.get_control2_val_droop_at(t_idx)
data.control2_droop_val[ii] = elm.get_control2_droop_val_at(t_idx)
data.control2_droop_val_min[ii] = elm.control2_droop_val_min
data.control2_droop_val_max[ii] = elm.control2_droop_val_max
# Using DC_positive to set the controls, may need to also pass DC_negative
set_control_dev(k=ii, f=f, t=t,
control_int=data.control1_int[ii],
control_dev=elm.get_control1_dev_at(t_idx),
control_val=data.control1_val[ii],
control_bus_idx=data.control1_bus_idx,
control_branch_idx=data.control1_branch_idx,
bus_dict=bus_dict,
bus_data=bus_data,
bus_voltage_used=bus_voltage_used,
bus_angle_used=bus_angle_used,
use_stored_guess=use_stored_guess,
logger=logger)
set_control_dev(k=ii, f=f, t=t,
control_int=data.control2_int[ii],
control_dev=elm.get_control2_dev_at(t_idx),
control_val=data.control2_val[ii],
control_bus_idx=data.control2_bus_idx,
control_branch_idx=data.control2_branch_idx,
bus_dict=bus_dict,
bus_data=bus_data,
bus_voltage_used=bus_voltage_used,
bus_angle_used=bus_angle_used,
use_stored_guess=use_stored_guess,
logger=logger)
data.contingency_enabled[i] = int(elm.contingency_enabled)
data.monitor_loading[i] = int(elm.monitor_loading)
# data.Kdp[ii] = elm.kdp
data.alpha1[ii] = elm.alpha1
data.alpha2[ii] = elm.alpha2
data.alpha3[ii] = elm.alpha3
data.min_ac_voltage[ii] = elm.min_ac_voltage
data.ysvs[ii] = elm.ysvs
ii += 1
[docs]
def get_hvdc_data(data: HvdcData,
circuit: MultiCircuit,
bus_dict,
bus_data: BusData,
bus_voltage_used: BoolVec,
t_idx: int | None,
opf_results: Union[OptimalPowerFlowResults, OptimalNetTransferCapacityResults, None] = None,
use_stored_guess: bool = False,
logger: Logger = Logger()):
"""
:param data:
:param circuit:
:param bus_dict:
:param bus_data:
:param bus_voltage_used:
:param t_idx:
:param opf_results:
:param use_stored_guess:
:param logger:
:return:
"""
# HVDC
for i, elm in enumerate(circuit.hvdc_lines):
# generic stuff
f = bus_dict[elm.bus_from]
t = bus_dict[elm.bus_to]
data.original_idx[i] = i
data.dispatchable[i] = int(elm.dispatchable)
data.F[i] = f
data.T[i] = t
# hvdc values
data.names[i] = elm.name
data.idtag[i] = elm.idtag
data.active[i] = elm.get_active_at(t_idx)
data.rates[i] = elm.get_rate_at(t_idx)
data.contingency_rates[i] = data.rates[i] * elm.get_contingency_factor_at(t_idx)
data.protection_rates[i] = data.rates[i] * elm.get_protection_rating_factor_at(t_idx)
data.angle_droop[i] = elm.get_angle_droop_at(t_idx)
data.r[i] = elm.r
if opf_results is not None:
# if we are taking the values from the OPF, do not allow the free mode
data.control_mode_int[i] = HvdcControlType.type_1_Pset.idx()
data.Pset[i] = opf_results.hvdc_Pf[t_idx, i]
else:
data.control_mode_int[i] = elm.control_mode.idx()
data.Pset[i] = elm.get_Pset_at(t_idx)
data.Vset_f[i] = elm.get_Vset_f_at(t_idx)
data.Vset_t[i] = elm.get_Vset_t_at(t_idx)
# hack the bus types to believe they are PV
if data.active[i] != 0:
set_bus_control_voltage_hvdc(i=f,
j=-1,
remote_control=False,
bus_name=elm.bus_from.name,
bus_data=bus_data,
bus_voltage_used=bus_voltage_used,
candidate_Vm=data.Vset_f[i],
use_stored_guess=use_stored_guess,
logger=logger)
set_bus_control_voltage_hvdc(i=t,
j=-1,
remote_control=False,
bus_name=elm.bus_to.name,
bus_data=bus_data,
bus_voltage_used=bus_voltage_used,
candidate_Vm=data.Vset_t[i],
use_stored_guess=use_stored_guess,
logger=logger)
data.Vnf[i] = elm.bus_from.Vnom
data.Vnt[i] = elm.bus_to.Vnom
data.Qmin_f[i], data.Qmax_f[i], data.Qmin_t[i], data.Qmax_t[i] = elm.get_q_limits(P=data.Pset[i])
[docs]
def get_fluid_node_data(data: FluidNodeData,
circuit: MultiCircuit,
t_idx: int | None = None,
logger: Logger = Logger()) -> Dict[str, int]:
"""
:param data:
:param circuit:
:param t_idx:
:param logger:
:return:
"""
plant_dict: Dict[str, int] = dict()
for k, elm in enumerate(circuit.get_fluid_nodes()):
plant_dict[elm.idtag] = k
data.names[k] = elm.name
data.idtag[k] = elm.idtag
# Convert input data in hm3 to m3
min_level, max_level = normalize_upper_bound(
lower=1e6 * elm.min_level,
upper=1e6 * elm.max_level,
logger=logger,
device_name=elm.name,
device_class=str(elm.device_type.value),
lower_name="min_level",
upper_name="max_level",
)
data.min_level[k] = min_level
data.max_level[k] = max_level
data.initial_level[k] = 1e6 * elm.initial_level
data.inflow[k] = elm.get_inflow_at(t_idx)
data.spillage_cost[k] = elm.get_spillage_cost_at(t_idx)
min_soc, max_soc = normalize_upper_bound(
lower=elm.get_min_soc_at(t_idx),
upper=elm.get_max_soc_at(t_idx),
logger=logger,
device_name=elm.name,
device_class=str(elm.device_type.value),
lower_name="min_soc",
upper_name="max_soc",
)
data.max_soc[k] = max_soc
data.min_soc[k] = min_soc
return plant_dict
[docs]
def resize_fluid_injection_data(data: FluidTurbineData, nelm: int) -> None:
"""
Resize fluid injection data arrays to the valid compiled entries.
:param data: Fluid injection data structure.
:param nelm: Number of valid compiled entries.
:return: None.
"""
if data.nelm == nelm:
pass
else:
data.names = data.names[:nelm].copy()
data.idtag = data.idtag[:nelm].copy()
data.efficiency = data.efficiency[:nelm].copy()
data.max_flow_rate = data.max_flow_rate[:nelm].copy()
data.plant_idx = data.plant_idx[:nelm].copy()
data.generator_idx = data.generator_idx[:nelm].copy()
data.nelm = nelm
[docs]
def get_valid_fluid_injection_indices(elm: FluidInjectionTemplate,
plant_dict: Dict[str, int],
gen_dict: Dict[str, int],
logger: Logger) -> tuple[int | None, int | None]:
"""
Resolve the plant and generator indices for one fluid injection.
:param elm: Fluid injection device.
:param plant_dict: Fluid node index by idtag.
:param gen_dict: Generator index by idtag.
:param logger: Logger receiving invalid-link errors.
:return: Plant and generator indices, or ``None`` for invalid links.
"""
plant_idx: int | None = None
gen_idx: int | None = None
if elm.plant is None:
logger.add_error(msg="Fluid injection has no plant",
device=elm.name,
device_class=str(elm.device_type.value),
device_property="plant")
else:
plant_idx = plant_dict.get(elm.plant.idtag, None)
if plant_idx is None:
logger.add_error(msg="Fluid injection plant is not in the compiled fluid nodes",
device=elm.name,
device_class=str(elm.device_type.value),
device_property="plant",
object_value=elm.plant.name)
else:
pass
if elm.generator is None:
logger.add_error(msg="Fluid injection has no generator",
device=elm.name,
device_class=str(elm.device_type.value),
device_property="generator")
else:
gen_idx = gen_dict.get(elm.generator.idtag, None)
if gen_idx is None:
logger.add_error(msg="Fluid injection generator is not in the compiled generators",
device=elm.name,
device_class=str(elm.device_type.value),
device_property="generator",
object_value=elm.generator.name)
else:
pass
return plant_idx, gen_idx
[docs]
def get_fluid_turbine_data(data: FluidTurbineData,
circuit: MultiCircuit,
plant_dict: Dict[str, int],
gen_dict: Dict[str, int],
logger: Logger = Logger()) -> FluidTurbineData:
"""
:param data:
:param circuit:
:param plant_dict:
:param gen_dict:
:param logger:
:return:
"""
k: int = 0
for elm in circuit.get_fluid_turbines():
plant_idx, gen_idx = get_valid_fluid_injection_indices(elm=elm,
plant_dict=plant_dict,
gen_dict=gen_dict,
logger=logger)
if plant_idx is not None and gen_idx is not None:
data.plant_idx[k] = plant_idx
data.generator_idx[k] = gen_idx
data.names[k] = elm.name
data.idtag[k] = elm.idtag
data.efficiency[k] = elm.efficiency
data.max_flow_rate[k] = elm.max_flow_rate
k += 1
else:
pass
resize_fluid_injection_data(data=data, nelm=k)
return data
[docs]
def get_fluid_pump_data(data: FluidPumpData,
circuit: MultiCircuit,
plant_dict: Dict[str, int],
gen_dict: Dict[str, int],
logger: Logger = Logger()) -> FluidPumpData:
"""
:param data:
:param circuit:
:param plant_dict:
:param gen_dict:
:param logger:
:return:
"""
k: int = 0
for elm in circuit.get_fluid_pumps():
plant_idx, gen_idx = get_valid_fluid_injection_indices(elm=elm,
plant_dict=plant_dict,
gen_dict=gen_dict,
logger=logger)
if plant_idx is not None and gen_idx is not None:
data.plant_idx[k] = plant_idx
data.generator_idx[k] = gen_idx
data.names[k] = elm.name
data.idtag[k] = elm.idtag
data.efficiency[k] = elm.efficiency
data.max_flow_rate[k] = elm.max_flow_rate
k += 1
else:
pass
resize_fluid_injection_data(data=data, nelm=k)
return data
[docs]
def get_fluid_p2x_data(data: FluidP2XData,
circuit: MultiCircuit,
plant_dict: Dict[str, int],
gen_dict: Dict[str, int],
logger: Logger = Logger()) -> FluidP2XData:
"""
:param data:
:param circuit:
:param plant_dict:
:param gen_dict:
:param logger:
:return:
"""
k: int = 0
for elm in circuit.get_fluid_p2xs():
plant_idx, gen_idx = get_valid_fluid_injection_indices(elm=elm,
plant_dict=plant_dict,
gen_dict=gen_dict,
logger=logger)
if plant_idx is not None and gen_idx is not None:
data.plant_idx[k] = plant_idx
data.generator_idx[k] = gen_idx
data.names[k] = elm.name
data.idtag[k] = elm.idtag
data.efficiency[k] = elm.efficiency
data.max_flow_rate[k] = elm.max_flow_rate
k += 1
else:
pass
resize_fluid_injection_data(data=data, nelm=k)
return data
[docs]
def get_fluid_path_data(data: FluidPathData,
circuit: MultiCircuit,
plant_dict: Dict[str, int],
logger: Logger = Logger()) -> FluidPathData:
"""
:param data: FluidPathData
:param circuit:
:param plant_dict:
:param logger:
:return:
"""
for k, elm in enumerate(circuit.get_fluid_paths()):
data.names[k] = elm.name
data.idtag[k] = elm.idtag
# pass idx, check
data.source_idx[k] = plant_dict[elm.source.idtag]
data.target_idx[k] = plant_dict[elm.target.idtag]
min_flow, max_flow = normalize_upper_bound(
lower=elm.min_flow,
upper=elm.max_flow,
logger=logger,
device_name=elm.name,
device_class=str(elm.device_type.value),
lower_name="min_flow",
upper_name="max_flow",
)
data.min_flow[k] = min_flow
data.max_flow[k] = max_flow
return data
[docs]
def compile_numerical_circuit_at(circuit: MultiCircuit,
t_idx: Union[int, None] = None,
apply_temperature: bool = False,
branch_tolerance_mode=BranchImpedanceMode.Specified,
opf_results: VALID_OPF_RESULTS | None = None,
use_stored_guess: bool = False,
bus_dict: Union[Dict[Bus, int], None] = None,
areas_dict: Union[Dict[Area, int], None] = None,
control_taps_modules: bool = True,
control_taps_phase: bool = True,
control_remote_voltage: bool = True,
fill_gep: bool = False,
fill_three_phase: bool = False,
consider_grounded_buses: bool = False,
logger: Logger = Logger()) -> NumericalCircuit:
"""
Compile a NumericalCircuit from a MultiCircuit
:param circuit: MultiCircuit instance
:param t_idx: time step from the time series to gather data from, if None the snapshot is used
:param apply_temperature: apply the branch temperature correction
:param branch_tolerance_mode: Branch tolerance mode
:param opf_results:(optional) OptimalPowerFlowResults instance
:param use_stored_guess: use the storage voltage guess?
:param bus_dict (optional) Dict[Bus, int] dictionary
:param areas_dict (optional) Dict[Area, int] dictionary
:param control_taps_modules: control taps modules?
:param control_taps_phase: control taps phase?
:param control_remote_voltage: control remote voltage?
:param fill_gep: fill generation expansion planning parameters?
:param fill_three_phase:
:param consider_grounded_buses: Consider the is_grounded bus state
:param logger: Logger instance
:return: NumericalCircuit instance
"""
# if any valid time index is specified, then the data is compiled from the time series
time_series = t_idx is not None
bus_voltage_used = np.zeros(circuit.get_bus_number(), dtype=bool)
ngen = circuit.get_generators_number()
nbatt = circuit.get_batteries_number()
# declare the numerical circuit
nc = NumericalCircuit(
nbus=circuit.get_bus_number(),
nbr=circuit.get_branch_number(add_vsc=False,
add_hvdc=False,
add_switch=True),
nhvdc=circuit.get_hvdc_number(),
nvsc=circuit.get_vsc_number(),
nload=circuit.get_load_like_device_number(),
ngen=ngen,
nbatt=nbatt,
nshunt=circuit.get_shunt_like_device_number(),
nfluidnode=circuit.get_fluid_nodes_number(),
nfluidturbine=circuit.get_fluid_turbines_number(),
nfluidpump=circuit.get_fluid_pumps_number(),
nfluidp2x=circuit.get_fluid_p2xs_number(),
nfluidpath=circuit.get_fluid_paths_number(),
sbase=circuit.Sbase,
t_idx=t_idx
)
if bus_dict is None:
bus_dict = {bus: i for i, bus in enumerate(circuit.buses)}
if areas_dict is None:
areas_dict = {elm: i for i, elm in enumerate(circuit.areas)}
get_bus_data(
bus_data=nc.bus_data, # filled here
circuit=circuit,
t_idx=t_idx,
areas_dict=areas_dict,
use_stored_guess=use_stored_guess,
consider_grounded_buses=consider_grounded_buses,
logger=logger,
)
gen_dict = get_generator_data(
data=nc.generator_data, # filled here
circuit=circuit,
bus_dict=bus_dict,
bus_data=nc.bus_data,
t_idx=t_idx,
time_series=time_series,
bus_voltage_used=bus_voltage_used,
logger=logger,
opf_results=opf_results,
control_remote_voltage=control_remote_voltage,
use_stored_guess=use_stored_guess,
fill_three_phase=fill_three_phase
)
get_battery_data(
data=nc.battery_data, # filled here
circuit=circuit,
bus_dict=bus_dict,
bus_data=nc.bus_data,
t_idx=t_idx,
time_series=time_series,
bus_voltage_used=bus_voltage_used,
logger=logger,
opf_results=opf_results,
control_remote_voltage=control_remote_voltage,
fill_three_phase=fill_three_phase
)
get_shunt_data(
data=nc.shunt_data, # filled here
circuit=circuit,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
bus_data=nc.bus_data,
t_idx=t_idx,
logger=logger,
use_stored_guess=use_stored_guess,
control_remote_voltage=control_remote_voltage,
fill_three_phase=fill_three_phase
)
get_load_data(
data=nc.load_data,
circuit=circuit,
bus_dict=bus_dict,
bus_voltage_used=bus_voltage_used,
bus_data=nc.bus_data,
t_idx=t_idx,
logger=logger,
use_stored_guess=use_stored_guess,
opf_results=opf_results,
fill_three_phase=fill_three_phase
)
branch_dict = get_branch_data(
data=nc.passive_branch_data,
ctrl_data=nc.active_branch_data,
circuit=circuit,
t_idx=t_idx,
bus_dict=bus_dict,
bus_data=nc.bus_data,
bus_voltage_used=bus_voltage_used,
apply_temperature=apply_temperature,
branch_tolerance_mode=branch_tolerance_mode,
opf_results=opf_results,
use_stored_guess=use_stored_guess,
control_taps_modules=control_taps_modules,
control_taps_phase=control_taps_phase,
fill_three_phase=fill_three_phase
)
get_vsc_data(
data=nc.vsc_data,
circuit=circuit,
t_idx=t_idx,
bus_dict=bus_dict,
branch_dict=branch_dict,
bus_data=nc.bus_data,
bus_voltage_used=bus_voltage_used,
opf_results=opf_results,
use_stored_guess=use_stored_guess,
control_remote_voltage=control_remote_voltage,
)
get_hvdc_data(
data=nc.hvdc_data,
circuit=circuit,
t_idx=t_idx,
bus_dict=bus_dict,
bus_data=nc.bus_data,
bus_voltage_used=bus_voltage_used,
opf_results=opf_results,
use_stored_guess=use_stored_guess,
logger=logger
)
if len(circuit.fluid_nodes) > 0:
plant_dict = get_fluid_node_data(
data=nc.fluid_node_data,
circuit=circuit,
t_idx=t_idx,
logger=logger,
)
get_fluid_turbine_data(
data=nc.fluid_turbine_data,
circuit=circuit,
plant_dict=plant_dict,
gen_dict=gen_dict,
logger=logger,
)
nc.nfluidturbine = nc.fluid_turbine_data.nelm
get_fluid_pump_data(
data=nc.fluid_pump_data,
circuit=circuit,
plant_dict=plant_dict,
gen_dict=gen_dict,
logger=logger,
)
nc.nfluidpump = nc.fluid_pump_data.nelm
get_fluid_p2x_data(
data=nc.fluid_p2x_data,
circuit=circuit,
plant_dict=plant_dict,
gen_dict=gen_dict,
logger=logger,
)
nc.nfluidp2x = nc.fluid_p2x_data.nelm
get_fluid_path_data(
data=nc.fluid_path_data,
circuit=circuit,
plant_dict=plant_dict,
logger=logger,
)
if fill_gep:
# formulate the investment
gen_dict = {elm.idtag: (idx, elm) for idx, elm in enumerate(circuit.generators)}
batt_dict = {elm.idtag: (idx, elm) for idx, elm in enumerate(circuit.batteries)}
for investment in circuit.investments:
# search in generators
data = gen_dict.get(investment.device_idtag, None)
if data is not None:
idx, elm = data
if investment.CAPEX != 0.0: # overwrite the base capex
nc.generator_data.capex[idx] = investment.CAPEX
nc.generator_data.is_candidate[idx] = True
nc.generator_data.discount_rate[idx] = investment.group.discount_rate
else:
# search in batteries
data = batt_dict.get(investment.device_idtag, None)
if data is not None:
idx, elm = data
if investment.CAPEX != 0.0: # overwrite the base capex
nc.battery_data.capex[idx] = investment.CAPEX
nc.battery_data.is_candidate[idx] = True
nc.battery_data.discount_rate[idx] = investment.group.discount_rate
else:
logger.add_error("Could not find investment device", value=investment.device_idtag)
nc.bus_dict = bus_dict
nc.consolidate_information()
if nc.active_branch_data.any_pf_control is False:
if nc.vsc_data.nelm > 0:
nc.active_branch_data.any_pf_control = True
return nc