import os
from typing import Dict
import numpy as np
import VeraGridEngine.Devices as dev
from VeraGridEngine.enumerations import ShuntControlMode, GeneratorControlMode
from VeraGridEngine.basic_structures import Logger
try:
import pypowsybl as pp
PYPOWSYBL_AVAILABLE = True
except ImportError:
pp = None
PYPOWSYBL_AVAILABLE = False
[docs]
class IidmParser:
"""
Xiidm file parser
"""
def __init__(self, fname: str, logger: Logger | None = None):
"""
:param fname: xiidm file
"""
self.logger = Logger() if logger is None else logger
if os.path.exists(fname):
if PYPOWSYBL_AVAILABLE:
self.ps_grid = pp.network.load(fname)
else:
self.ps_grid = None
self.logger.add_error("pypowsybl not installed")
else:
self.ps_grid = None
[docs]
def parse(self) -> dev.MultiCircuit:
"""
Convert the PowSybl structures to deeac
:return: Network
"""
grid = dev.MultiCircuit()
if self.ps_grid is None:
return grid
else:
"""
- Expected objects:
- areas
- buses (from bus view)
- buses from bus/breaker view
- lines
- 2 windings transformers
- 3 windings transformers
- generators
- loads
- shunt compensators
- dangling lines
- LCC and VSC converters stations
- static var compensators
- switches
- voltage levels
- substations
- busbar sections
- HVDC lines
- ratio and phase tap changer steps associated to a 2 windings transformers
- identifiables that are all the equipment on the network
- injections
- branches (lines and two windings transformers)
- terminals are a practical view of those objects
which are very important in the java implementation
- DC nodes
- DC lines
- voltage source converters
- DC grounds
"""
substations = self.ps_grid.get_substations(all_attributes=True)
voltage_levels = self.ps_grid.get_voltage_levels(all_attributes=True)
buses = self.ps_grid.get_buses(all_attributes=True)
lines = self.ps_grid.get_lines(all_attributes=True)
# branches = self.ps_grid.get_branches(all_attributes=True)
switches = self.ps_grid.get_switches(all_attributes=True)
transformers2w = self.ps_grid.get_2_windings_transformers(all_attributes=True)
transformers3w = self.ps_grid.get_3_windings_transformers(all_attributes=True)
self.ps_grid.get_phase_tap_changers(all_attributes=True)
self.ps_grid.get_phase_tap_changer_steps(all_attributes=True)
hvdc = self.ps_grid.get_hvdc_lines(all_attributes=True)
loads = self.ps_grid.get_loads(all_attributes=True)
gens = self.ps_grid.get_generators(all_attributes=True)
capacitor_banks = self.ps_grid.get_shunt_compensators(all_attributes=True)
svc = self.ps_grid.get_static_var_compensators(all_attributes=True)
grid.name = self.ps_grid.name
grid.Sbase = self.ps_grid.nominal_apparent_power
is_in_pu = self.ps_grid.per_unit
"""
Substation
0 = {str} 'name'
1 = {str} 'TSO': To track to which Transmission System Operator the substation belongs
2 = {str} 'geo_tags': They make it possible to accurately locate the substation
3 = {str} 'country': To specify in which country the substation is located
4 = {str} 'fictitious'
"""
country_dict: Dict[str, dev.Country] = dict()
se_dict: Dict[str, dev.Substation] = dict()
for i, row in substations.iterrows():
country = country_dict.get(row["country"], None)
if country is None:
country = dev.Country(name=row["country"])
grid.add_country(obj=country)
country_dict[country.name] = country
name = row["name"]
if name == "":
name = i
elm = dev.Substation(
name=name,
code=i,
country=country
)
grid.add_substation(obj=elm)
se_dict[i] = elm
"""
Voltage Level
0 = {str} 'name'
1 = {str} 'substation_id'
2 = {str} 'nominal_v': kV, Nominal base voltage
3 = {str} 'high_voltage_limit' kV, Low voltage limit magnitude
4 = {str} 'low_voltage_limit' kV, High voltage limit magnitude
In the docs
(https://powsybl.readthedocs.io/projects/powsybl-core/en/stable/grid_model/network_subnetwork.html)
it says that topology_kind is required, but doesn't seem to be present
"""
vl_dict: Dict[str, dev.VoltageLevel] = dict()
for i, row in voltage_levels.iterrows():
se = se_dict.get(row["substation_id"], None)
if se is None:
self.logger.add_error("Substation not found",
value=row["substation_id"])
name = row["name"]
if name == "":
name = i
elm = dev.VoltageLevel(
name=name,
code=i,
Vnom=float(row["nominal_v"]),
substation=se
)
grid.add_voltage_level(obj=elm)
vl_dict[i] = elm
try:
topology = self.ps_grid.get_node_breaker_topology(voltage_level_id=i)
except pp.PyPowsyblError:
pass
"""
Bus
0 = {str} 'name'
1 = {str} 'v_mag'
2 = {str} 'v_angle'
3 = {str} 'connected_component'
4 = {str} 'synchronous_component'
5 = {str} 'voltage_level_id'
6 = {str} 'fictitious'
"""
bus_dict: Dict[str, dev.Bus] = dict()
for idx, row in buses.iterrows():
vl = vl_dict.get(row["voltage_level_id"], None)
if vl is None:
self.logger.add_error("Voltage level not found",
value=row["voltage_level_id"])
bus = dev.Bus(
name=row["name"] if row["name"] != "" else idx,
code=idx,
Vnom=10 if vl is None else vl.Vnom,
Vm0=float(row["v_mag"]),
Va0=float(row["v_angle"]),
voltage_level=vl
)
grid.add_bus(obj=bus)
bus_dict[idx] = bus
"""
Line
00 = {str} 'name'
01 = {str} 'r'
02 = {str} 'x'
03 = {str} 'g1'
04 = {str} 'b1'
05 = {str} 'g2'
06 = {str} 'b2'
07 = {str} 'p1'
08 = {str} 'q1'
09 = {str} 'i1'
10 = {str} 'p2'
11 = {str} 'q2'
12 = {str} 'i2'
13 = {str} 'voltage_level1_id'
14 = {str} 'voltage_level2_id'
15 = {str} 'bus1_id'
16 = {str} 'bus_breaker_bus1_id'
17 = {str} 'node1'
18 = {str} 'bus2_id'
19 = {str} 'bus_breaker_bus2_id'
20 = {str} 'node2'
21 = {str} 'connected1'
22 = {str} 'connected2'
23 = {str} 'fictitious'
24 = {str} 'selected_limits_group_1'
25 = {str} 'selected_limits_group_2'
"""
for i, row in lines.iterrows():
bus1: dev.Bus | None = bus_dict.get(row["bus1_id"], None)
bus2: dev.Bus | None = bus_dict.get(row["bus2_id"], None)
if bus1 is None:
self.logger.add_error("Bus from not found",
device_class="Line",
device=i)
if bus2 is None:
self.logger.add_error("Bus to not found",
device_class="Line",
device=i)
if bus1 is not None and bus2 is not None:
Vn = max(bus1.Vnom, bus2.Vnom)
Zbase = Vn * Vn / grid.Sbase
Ybase = 1.0 / Zbase
elm = dev.Line(
name=row["name"] if row["name"] != "" else i,
code=i,
bus_from=bus1,
bus_to=bus2,
r=row["r"] / Zbase,
x=row["x"] / Zbase,
b=row["b1"] / Ybase,
)
grid.add_line(obj=elm, logger=self.logger)
else:
pass
"""
Switch
00 = {str} 'name'
01 = {str} 'kind' {'DISCONNECTOR', 'BREAKER'}
02 = {str} 'open'
03 = {str} 'retained'
04 = {str} 'voltage_level_id'
05 = {str} 'bus_breaker_bus1_id'
06 = {str} 'bus_breaker_bus2_id'
07 = {str} 'node1'
08 = {str} 'node2'
09 = {str} 'fictitious'
"""
# TODO: Unclear when these are available or how they're connected
# for i, row in switches.iterrows():
# bus1: dev.Bus = bus_dict[row["bus_breaker_bus1_id"]]
# bus2: dev.Bus = bus_dict[row["bus_breaker_bus2_id"]]
#
# elm = dev.Switch(
# name=row["name"],
# code = i,
# bus_from=bus1,
# bus_to=bus2,
# retained=bool(row["retained"]),
# active=not bool(row["open"])
# )
#
# grid.add_switch(obj=elm)
"""
Transformer
https://powsybl.readthedocs.io/projects/pypowsybl/en/stable/reference/api/pypowsybl.network.Network.get_2_windings_transformers.html#pypowsybl.network.Network.get_2_windings_transformers
00 = {str} 'name'
01 = {str} 'r': the resistance of the transformer at its β2β side (in Ohm)
02 = {str} 'x': x: the reactance of the transformer at its β2β side (in Ohm)
03 = {str} 'g': b: the susceptance of transformer at its β2β side (in Siemens)
04 = {str} 'b': the conductance of transformer at its β2β side (in Siemens)
05 = {str} 'rated_u1': the rated voltage of the transformer at side 1 (in kV)
06 = {str} 'rated_u2': the rated voltage of the transformer at side 2 (in kV)
07 = {str} 'rated_s': the rated apparent power of the transformer (in MVA)
08 = {str} 'p1': the active flow on the transformer at its β1β side, NaN if no loadflow has been computed (in MW)
09 = {str} 'q1': the reactive flow on the transformer at its β1β side, NaN if no loadflow has been computed (in MVAr)
10 = {str} 'i1': the current on the transformer at its β1β side, NaN if no loadflow has been computed (in A)
11 = {str} 'p2'
12 = {str} 'q2'
13 = {str} 'i2'
14 = {str} 'voltage_level1_id': voltage level where the transformer is connected, on side 1
15 = {str} 'voltage_level2_id': voltage level where the transformer is connected, on side 2
16 = {str} 'bus1_id': bus where this transformer is connected, on side 1
17 = {str} 'bus_breaker_bus1_id' (optional): bus of the bus-breaker view where this transformer is connected, on side 1
18 = {str} 'node1': (optional): node where this transformer is connected on side 1, in node-breaker voltage levels
19 = {str} 'bus2_id': bus where this transformer is connected, on side 2
20 = {str} 'bus_breaker_bus2_id'
21 = {str} 'node2'
22 = {str} 'connected1': the side β1β of the transformer is connected to a bus
23 = {str} 'connected2': the side β2β of the transformer is connected to a bus
24 = {str} 'fictitious': the transformer is part of the model and not of the actual network
25 = {str} 'selected_limits_group_1': (optional): Name of the selected operational limits group selected for side 1
26 = {str} 'selected_limits_group_2': (optional): Name of the selected operational limits group selected for side 2
27 = {str} 'rho'(optional): the voltage ratio of the transformer at current tap position
28 = {str} 'alpha'(optional): the phase shift of the transformer at current tap position (in degree)
29 = {str} 'r_at_current_tap'(optional): the resistance of the transformer at current tap position (in Ohm)
30 = {str} 'x_at_current_tap'(optional): the reactance of the transformer at current tap position (in Ohm)
31 = {str} 'g_at_current_tap'(optional): the susceptance of the transformer at current tap position (in Ohm)
32 = {str} 'b_at_current_tap'(optional): the conductance of the transformer at current tap position (in Ohm)
"""
for i, row in transformers2w.iterrows():
bus1: dev.Bus | None = bus_dict.get(row["bus1_id"], None)
bus2: dev.Bus | None = bus_dict.get(row["bus2_id"], None)
if bus1 is None:
self.logger.add_error("Bus from not found",
device_class="Line",
device=i)
if bus2 is None:
self.logger.add_error("Bus to not found",
device_class="Line",
device=i)
if bus1 is not None and bus2 is not None:
rated_u1 = float(row["rated_u1"])
rated_u2 = float(row["rated_u2"])
if rated_u1 > rated_u2:
HV = rated_u1
LV = rated_u2
else:
HV = rated_u2
LV = rated_u1
Sn = float(row["rated_s"])
if np.isnan(Sn):
Sn = 9999.0
# The per unit is referred to the bus 2
Zbase = bus2.Vnom * bus2.Vnom / grid.Sbase
Ybase = 1.0 / Zbase
r = float(row["r"]) / Zbase
x = float(row["x"]) / Zbase
g = float(row["g"]) / Ybase
b = float(row["b"]) / Ybase
elm = dev.Transformer2W(
name=row["name"] if row["name"] != "" else i,
code=i,
bus_from=bus1,
bus_to=bus2,
r=r,
x=x,
g=g,
b=b,
HV=HV,
LV=LV,
rate=Sn,
tap_module=float(row["rho"]),
tap_phase=float(row["alpha"]), # TODO in deg or rad? we need rad
)
grid.add_transformer2w(obj=elm)
else:
pass
"""
rated_u0: the rated voltage of the transformer at middle point od the star model (in kV)
fictitious (optional): True if the transformer is part of the model and not of the actual network
r1: the leg 1 resistance of the transformer (in Ohm)
x1: the leg 1 reactance of the transformer (in Ohm)
b1: the leg 1 susceptance of transformer (in Siemens)
g1: the leg 1 conductance of transformer (in Siemens)
rated_u1: the leg 1 rated voltage of the transformer (in kV)
rated_s1: the leg 1 rated apparent power of the transformer (in MVA)
ratio_tap_position1: the leg 1 ratio tap changer current position
phase_tap_position1: the leg 1 phase tap changer current position
p1: the leg 1 active power flow on the transformer, NaN if no loadflow has been computed (in MW)
q1: the leg 1 reactive power flow on the transformer, NaN if no loadflow has been computed (in MVAr)
i1: the leg 1 current on the transformer, NaN if no loadflow has been computed (in A)
voltage_level1_id: the voltage level where the leg 1 of the transformer is connected
bus1_id: the bus where the leg 1 of the transformer is connected
bus_breaker_bus1_id (optional): the bus of the bus-breaker view where leg 1 of the transformer is connected
node1 (optional): the node where the leg 1 transformer is connected (only in node-breaker voltage levels)
connected1: True if the leg 1 of the transformer is connected to a bus
selected_limits_group_1 (optional): the name of the selected operational limits group selected for the leg 1 of the transformer
rho1 (optional): the leg 1 voltage ratio of the transformer at current tap position
alpha1 (optional): the leg 1 phase shift of the transformer at current tap position (in degree)
r1_at_current_tap (optional): the leg 1 resistance of the transformer at current tap position (in Ohm)
x1_at_current_tap (optional): the leg 1 reactance of the transformer at current tap position (in Ohm)
g1_at_current_tap (optional): the leg 1 susceptance of the transformer at current tap position (in Ohm)
b1_at_current_tap (optional): the leg 1 conductance of the transformer at current tap position (in Ohm)
r2: the leg 2 resistance of the transformer (in Ohm)
x2: the leg 2 reactance of the transformer (in Ohm)
b2: the leg 2 susceptance of transformer (in Siemens)
g2: the leg 2 conductance of transformer (in Siemens)
rated_u2: the leg 2 rated voltage of the transformer (in kV)
rated_s2: the leg 2 rated apparent power of the transformer (in MVA)
ratio_tap_position2: the leg 2 ratio tap changer current position
phase_tap_position2: the leg 2 phase tap changer current position
p2: the leg 2 active power flow on the transformer, NaN if no loadflow has been computed (in MW)
q2: the leg 2 reactive power flow on the transformer, NaN if no loadflow has been computed (in MVAr)
i2: the leg 2 current on the transformer, NaN if no loadflow has been computed (in A)
voltage_level2_id: the voltage level where the leg 2 of the transformer is connected
bus2_id: the bus where the leg 2 of the transformer is connected
bus_breaker_bus2_id (optional): the bus of the bus-breaker view where leg 2 of the transformer is connected
node2 (optional): the node where the leg 2 transformer is connected (only in node-breaker voltage levels)
connected2: True if the leg 2 of the transformer is connected to a bus
selected_limits_group_2 (optional): the name of the selected operational limits group selected for the leg 2 of the transformer
rho2 (optional): the leg 2 voltage ratio of the transformer at current tap position
alpha2 (optional): the leg 2 phase shift of the transformer at current tap position (in degree)
r2_at_current_tap (optional): the leg 2 resistance of the transformer at current tap position (in Ohm)
x2_at_current_tap (optional): the leg 2 reactance of the transformer at current tap position (in Ohm)
g2_at_current_tap (optional): the leg 2 susceptance of the transformer at current tap position (in Ohm)
b2_at_current_tap (optional): the leg 2 conductance of the transformer at current tap position (in Ohm)
r3: the leg 3 resistance of the transformer (in Ohm)
x3: the leg 3 reactance of the transformer (in Ohm)
b3: the leg 3 susceptance of transformer (in Siemens)
g3: the leg 3 conductance of transformer (in Siemens)
rated_u3: the leg 3 rated voltage of the transformer (in kV)
rated_s3: the leg 3 rated apparent power of the transformer (in MVA)
ratio_tap_position3: the leg 3 ratio tap changer current position
phase_tap_position3: the leg 3 phase tap changer current position
p3: the leg 3 active power flow on the transformer, NaN if no loadflow has been computed (in MW)
q3: the leg 3 reactive power flow on the transformer, NaN if no loadflow has been computed (in MVAr)
i3: the leg 3 current on the transformer, NaN if no loadflow has been computed (in A)
voltage_level3_id: the voltage level where the leg 3 of the transformer is connected
bus3_id: the bus where the leg 3 of the transformer is connected
bus_breaker_bus3_id (optional): the bus of the bus-breaker view where leg 3 of the transformer is connected
node3 (optional): the node where the leg 3 transformer is connected (only in node-breaker voltage levels)
connected3: True if the leg 3 of the transformer is connected to a bus
selected_limits_group_3 (optional): the name of the selected operational limits group selected for the leg 3 of the transformer
rho3 (optional): the leg 3 voltage ratio of the transformer at current tap position
alpha3 (optional): the leg 3 phase shift of the transformer at current tap position (in degree)
r3_at_current_tap (optional): the leg 3 resistance of the transformer at current tap position (in Ohm)
x3_at_current_tap (optional): the leg 3 reactance of the transformer at current tap position (in Ohm)
g3_at_current_tap (optional): the leg 3 susceptance of the transformer at current tap position (in Ohm)
b3_at_current_tap (optional): the leg 3 conductance of the transformer at current tap position (in Ohm)
"""
for i, row in transformers3w.iterrows():
pass
"""
HVDC
00 = {str} 'name'
01 = {str} 'converters_mode'
02 = {str} 'target_p'
03 = {str} 'max_p'
04 = {str} 'nominal_v'
05 = {str} 'r'
06 = {str} 'converter_station1_id'
07 = {str} 'converter_station2_id'
08 = {str} 'connected1'
09 = {str} 'connected2'
10 = {str} 'fictitious'
"""
for i, row in hvdc.iterrows():
bus1: dev.Bus | None = bus_dict.get(row["converter_station1_id"], None)
bus2: dev.Bus | None = bus_dict.get(row["converter_station2_id"], None)
if bus1 is None:
self.logger.add_error("Bus from not found",
device_class="Line",
device=i)
if bus2 is None:
self.logger.add_error("Bus to not found",
device_class="Line",
device=i)
if bus1 is not None and bus2 is not None:
connected1 = bool(row["connected1"])
connected2 = bool(row["connected2"])
# TODO, what is the content of converters_mode? PMODE1, PMODE3 stuff probably but investigate
elm = dev.HvdcLine(
name=row["name"] if row["name"] != "" else i,
bus_from=bus1,
bus_to=bus2,
dc_link_voltage=float(row["nominal_v"]),
Pset=float(row["target_p"]),
rate=float(row["max_p"]),
r=float(row["r"]), # TODO: Ohm?, we need Ohm
active=connected1 and connected2
)
grid.add_hvdc(obj=elm)
"""
Load
00 = {str} 'name'
01 = {str} 'type'
02 = {str} 'p0'
03 = {str} 'q0'
04 = {str} 'p'
05 = {str} 'q'
06 = {str} 'i'
07 = {str} 'voltage_level_id'
08 = {str} 'bus_id'
09 = {str} 'bus_breaker_bus_id'
10 = {str} 'node'
11 = {str} 'connected'
12 = {str} 'fictitious'
"""
for i, row in loads.iterrows():
bus1: dev.Bus | None = bus_dict.get(row["bus_id"], None)
if bus1 is None:
self.logger.add_error("Bus not found",
device_class="Load",
device=i)
else:
elm = dev.Load(
name=row["name"] if row["name"] != "" else i,
code=i,
P1=float(row["p"]),
Q1=float(row["q"]),
active=bool(row["connected"])
)
grid.add_load(bus=bus1, api_obj=elm)
"""
Generator
00 = {str} 'name'
01 = {str} 'energy_source'
02 = {str} 'target_p' MW, The active power target
03 = {str} 'min_p' MW, Minimum generator active power output
04 = {str} 'max_p' MW, Maximum generator active power output
05 = {str} 'min_q' MVAr
06 = {str} 'max_q' MVAr
07 = {str} 'min_q_at_target_p'
08 = {str} 'max_q_at_target_p'
09 = {str} 'min_q_at_p'
10 = {str} 'max_q_at_p'
11 = {str} 'rated_s' MVA, The rated nominal power
12 = {str} 'reactive_limits_kind'
13 = {str} 'target_v' kV, The voltage target at regulating terminal which can be remote or local
14 = {str} 'target_q' MVAr, The reactive power target at local terminal
15 = {str} 'voltage_regulator_on'
16 = {str} 'regulated_element_id'
17 = {str} 'regulated_bus_id'
18 = {str} 'regulated_bus_breaker_bus_id'
19 = {str} 'p'
20 = {str} 'q'
21 = {str} 'i'
22 = {str} 'voltage_level_id'
23 = {str} 'bus_id'
24 = {str} 'bus_breaker_bus_id'
25 = {str} 'node'
26 = {str} 'condenser'
27 = {str} 'connected'
28 = {str} 'fictitious'
"""
for i, row in gens.iterrows():
bus1: dev.Bus | None = bus_dict.get(row["bus_id"], None)
if bus1 is None:
self.logger.add_error("Bus not found",
device_class="Generator",
device=i)
else:
p = float(row["p"])
q = float(row["q"])
S = p + 1j * q
Sabs = abs(S)
if bool(row["voltage_regulator_on"]):
control_mode = GeneratorControlMode.V
else:
control_mode = GeneratorControlMode.Q
elm = dev.Generator(
name=row["name"] if row["name"] != "" else i,
code=i,
P=p,
Q=q,
vset=float(row["target_v"]),
Pmin=float(row["min_p"]),
Pmax=float(row["max_p"]),
Qmin=float(row["min_q"]),
Qmax=float(row["max_q"]),
Snom=float(row["rated_s"]),
active=bool(row["connected"]),
control_mode=control_mode,
)
elm.control_bus = bus_dict.get(row["regulated_bus_id"], None)
grid.add_generator(bus=bus1, api_obj=elm)
"""
Capacitor bank
00 = {str} 'name'
01 = {str} 'g'
02 = {str} 'b'
03 = {str} 'model_type'
04 = {str} 'max_section_count'
05 = {str} 'section_count'
06 = {str} 'solved_section_count'
07 = {str} 'voltage_regulation_on'
08 = {str} 'target_v'
09 = {str} 'target_deadband'
10 = {str} 'regulating_bus_id'
11 = {str} 'p'
12 = {str} 'q'
13 = {str} 'i'
14 = {str} 'voltage_level_id'
15 = {str} 'bus_id'
16 = {str} 'bus_breaker_bus_id'
17 = {str} 'node'
18 = {str} 'connected'
19 = {str} 'fictitious'
"""
for i, row in capacitor_banks.iterrows():
bus1: dev.Bus | None = bus_dict.get(row["bus_id"], None)
if bus1 is None:
self.logger.add_error("Bus not found",
device_class="Capacitor Bank",
device=i)
else:
elm = dev.Shunt(
name=row["name"] if row["name"] != "" else i,
code=i,
G1=float(row["g"]),
B1=float(row["b"]),
active=bool(row["connected"])
)
grid.add_shunt(bus=bus1, api_obj=elm)
"""
SVC
00 = {str} 'name'
01 = {str} 'b_min'
02 = {str} 'b_max'
03 = {str} 'target_v'
04 = {str} 'target_q'
05 = {str} 'regulation_mode'
06 = {str} 'regulating'
07 = {str} 'regulated_element_id'
08 = {str} 'regulated_bus_id'
09 = {str} 'regulated_bus_breaker_bus_id'
10 = {str} 'p'
11 = {str} 'q'
12 = {str} 'i'
13 = {str} 'voltage_level_id'
14 = {str} 'bus_id'
15 = {str} 'bus_breaker_bus_id'
16 = {str} 'node'
17 = {str} 'connected'
18 = {str} 'fictitious'
"""
for i, row in svc.iterrows():
bus1: dev.Bus | None = bus_dict.get(row["bus_id"], None)
if bus1 is None:
self.logger.add_error("Bus not found",
device_class="SVC",
device=i)
else:
elm = dev.ControllableShunt(
name=row["name"] if row["name"] != "" else i,
code=i,
G1=float(row["p"]), # TODO: Make sure about the units
B1=float(row["q"]),
active=bool(row["connected"]),
Bmin=float(row["b_min"]),
Bmax=float(row["b_max"]),
vset=float(row["target_v"]),
control_mode=ShuntControlMode.Continuous if bool(row["regulating"]) else ShuntControlMode.Locked
)
elm.control_bus = bus_dict.get(row["regulated_bus_id"], None)
grid.add_controllable_shunt(bus=bus1, api_obj=elm)
return grid